Difference between revisions of "Carl Zeiss"
m (added EM109 image to list) |
|||
(4 intermediate revisions by 2 users not shown) | |||
Line 9: | Line 9: | ||
== Transmition Electron Microscopes == | == Transmition Electron Microscopes == | ||
=== Early Models === | === Early Models === | ||
− | {{Tem list entry|Microscope Name= | + | {{Tem list entry|Microscope Name=EM6|Microscope Picture File=Zeiss - EM8 - B. v. Bories.png|Year=|Successor=EM7|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electrostatic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}} |
+ | |||
+ | {{Tem list entry|Microscope Name=EM7|Microscope Picture File=https://www.dge-homepage.de/historische_dias/05_EM7_AEG_Elektrostat_TEM_1947.jpg|Year=1945|Successor=EM8|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=100KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electrostatic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=100 -200 nm|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}} | ||
{{Tem list entry|Microscope Name=EM8|Microscope Picture File=Zeiss - EM8.png|Year=|Successor=EM9|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electrostatic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}} | {{Tem list entry|Microscope Name=EM8|Microscope Picture File=Zeiss - EM8.png|Year=|Successor=EM9|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electrostatic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}} | ||
Line 262: | Line 264: | ||
[[Category:Electron Microscope]] | [[Category:Electron Microscope]] | ||
+ | [[Category:Pages with broken file links]] | ||
= Documentation = | = Documentation = | ||
Line 278: | Line 281: | ||
**EM8 | **EM8 | ||
*** Bedienungsanleitung | *** Bedienungsanleitung | ||
− | ****{"icon":false}{{#l:Zeiss - EM8 - Kurtzanleitung.pdf|Kurtzanleitung}} | + | ****{"icon":false}{{#l:Zeiss - EM8 - Kurtzanleitung.pdf|EM 8 - Kurtzanleitung}} |
+ | ****{"icon":false}{{#l:Zeiss - G 34-503-d - Elektronenmikroskop EM8 - Gebrauchsanweisung Text.pdf|G 34-503-d - Elektronenmikroskop EM8 - Gebrauchsanweisung Text}} | ||
+ | ****{"icon":false}{{#l:Zeiss - G 34-503-d - Elektronenmikroskop EM8 - Gebrauchsanweisung Bildteil.pdf|G 34-503-d - Elektronenmikroskop EM8 - Gebrauchsanweisung Bildteil}} | ||
**EM9A | **EM9A | ||
***Manuals | ***Manuals | ||
Line 284: | Line 289: | ||
***Brochüre | ***Brochüre | ||
****{"icon":false}{{#l:Zeiss - 34-547-d - EM9A Brochure.pdf|34-547-d - Elektronenmikroskop EM9A}} | ****{"icon":false}{{#l:Zeiss - 34-547-d - EM9A Brochure.pdf|34-547-d - Elektronenmikroskop EM9A}} | ||
+ | ****{"icon":false}{{#l:Zeiss - 34-554-d - EM9S2 - Brochure.pdf|34-554-d - Elektronenmikroskop EM9S-2}} | ||
**EM10 | **EM10 | ||
***Brochüre | ***Brochüre | ||
Line 300: | Line 306: | ||
}} | }} | ||
− | + | ||
== Scanning Electron Microscope == | == Scanning Electron Microscope == | ||
Line 317: | Line 323: | ||
}} | }} | ||
+ | = List of Scanning Electron Microscopes = | ||
+ | == Pre Cambridge Acquisition Models == | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! scope="row"| Model | ||
+ | ! scope="row"| Year | ||
+ | |- | ||
+ | |style="text-align:center;"|DSM950 | ||
+ | |style="text-align:center;"| | ||
+ | |- | ||
+ | |style="text-align:center;"|DSM940 | ||
+ | |style="text-align:center;"| | ||
+ | |- | ||
+ | |style="text-align:center;"|DSM940A | ||
+ | |style="text-align:center;"| | ||
+ | |- | ||
+ | |style="text-align:center;"|DSM960 | ||
+ | |style="text-align:center;"| | ||
+ | |- | ||
+ | |style="text-align:center;"|DSM962 | ||
+ | |style="text-align:center;"| | ||
+ | |} | ||
+ | == Post Cambridge Acquisition Models == | ||
= stuff = | = stuff = | ||
Latest revision as of 15:37, 14 January 2024
Zeiss is a German Manufactuer of Electron Microscopes, much like Siemens it was involved in the invention of the Electron Microsocpe. Originally its development focused on the creation of Electrostatic microscopes, but this approch was later abbandoned in favor of the Electromagnetic lens.
Only 2 models using exclusivly Electrostic Lenses are currently known to have existed, this is the experimental EM7, and the production EM8 microscope.
The EM9 marked the first all Electromagnetic Electron Microscope constructed by Carl Zeiss.
List of Models
Transmition Electron Microscopes
Early Models
EM6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
EM7 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
200px |
|
|
|
|
|
|
EM8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
EM9 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
General | |
---|---|
Year | 1947 |
Successor | EM8 |
Mag. Range | 1500x, 5000x, 15000x |
Electron Source | |
---|---|
Acellerating Voltage | 60 KV (50 KV) |
Objective | |
---|---|
Lens Type | Electrostatic |
Resolution | 20Å |
Projective Lens | |
---|---|
Lens Type | Electrostatic |
No. of Lenses | 2 |
General | |
---|---|
Successor | EM9 |
Mag. Range | 900x, 1.6Kx, 3Kx, 5Kx, 9Kx, 16Kx |
Electron Source | |
---|---|
Accelerator Type | Steigerwald remote focus Triode |
Acellerating Voltage | 60 KV |
Cathode | Tungsten Hairpin |
Objective | |
---|---|
Lens Type | Electrostatic |
Stigmator | Electrostatic Hexapol |
Resolution | 7-9Å |
Projective Lens | |
---|---|
Lens Type | Electrostatic |
No. of Lenses | 3 |
General | |
---|---|
Successor | EM10 |
Mag. Range | 1800x, 8000x, 26Kx, 60Kx, 0-60Kx |
Mag. Gauge | Text and Bulb |
Power Requirment | 1.8 KVA |
System Weight | 1320 lbs |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Acellerating Voltage | 60 KV |
Cathode | Tungsten Hairpin |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Nu. of Lenses | 1 |
Stage | |
---|---|
Holder Type | Side Entry |
Objective | |
---|---|
Lens Type | Electromagnetic |
Focal Length | 4mm |
Stigmator | Electrostatic Octopol |
Resolution | 7-9Å |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
No. of Lenses | 2 |
Configuration | Single Polpiece |
Orange Column Models
It should be noted that this list is far from complete, and many models are yet missing within!
General | |
---|---|
Successor | EM10A |
Mag. Range | 100x, 1000x - 200Kx |
Mag. Gauge | 7-Seg. Digital |
Chamber Pressure | 5*10⁻⁵ Torr |
Power Requirment | 3.5 KVA |
System Weight | 800 Kg |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Acellerating Voltage | 20, 40, 60, 80, 100 KV |
Stability | 2*10⁻⁶min |
Cathode | Tungsten Hairpin |
Cathode Heating | DC |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Nu. of Lenses | 2 |
Stability | 5*10⁻⁶/min |
Stigmator | Quadropol |
Spot Size | 1 µm |
Stage | |
---|---|
Holder Type | Cartridge, Top Entery |
Objective | |
---|---|
Lens Type | Electromagnetic |
Focal Length | 2.6mm |
Stability | 2*10⁻⁶/min |
Stigmator | Octopol |
Spherical Error | 2.2 mm |
Chromatic Error | 1.7 mm |
Resolution | 5Å |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
No. of Lenses | 2 |
Stability | 2*10⁻⁶/min |
Configuration | Single Polpiece |
Stigmator | Octopol |
General | |
---|---|
Successor | EM10C |
Mag. Range | 100x, 1000x - 200Kx |
Mag. Gauge | 7-Seg. Digital |
Chamber Pressure | 5*10⁻⁵ Torr |
Power Requirment | 3.5 KVA |
System Weight | 800 Kg |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Acellerating Voltage | 20, 40, 60, 80, 100 KV |
Stability | 2*10⁻⁶min |
Cathode | Tungsten Hairpin |
Cathode Heating | DC |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Nu. of Lenses | 2 |
Stability | 5*10⁻⁶/min |
Stigmator | Quadropol |
Spot Size | 1 µm |
Stage | |
---|---|
Holder Type | Cartridge, Top Entery |
Objective | |
---|---|
Lens Type | Electromagnetic |
Focal Length | 2.6mm |
Stability | 2*10⁻⁶/min |
Stigmator | Octopol |
Spherical Error | 2.2 mm |
Chromatic Error | 1.7 mm |
Resolution | 5Å |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
No. of Lenses | 2 |
Stability | 2*10⁻⁶/min |
Configuration | Single Polpiece |
Stigmator | Octopol |
General | |
---|---|
Successor | EM10CR |
Mag. Range | 100x, 1000x - 500Kx |
Mag. Gauge | 7-Seg. Digital |
Chamber Pressure | 5*10⁻⁵ Torr |
Power Requirment | 3.5 KVA |
System Weight | 800 Kg |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Acellerating Voltage | 20, 40, 60, 80, 100 KV |
Stability | 2*10⁻⁶min |
Cathode | Tungsten Hairpin |
Cathode Heating | DC |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Nu. of Lenses | 2 |
Stability | 5*10⁻⁶/min |
Stigmator | Quadropol |
Spot Size | 200 nm |
Stage | |
---|---|
Holder Type | Cartridge, Top Entery |
Objective | |
---|---|
Lens Type | Electromagnetic |
Focal Length | 2.6mm |
Stability | 2*10⁻⁶/min |
Stigmator | Octopol |
Spherical Error | 2.2 mm |
Chromatic Error | 1.7 mm |
Resolution | 3Å |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
No. of Lenses | 2 |
Stability | 2*10⁻⁶/min |
Configuration | Single Polpiece |
Stigmator | Octopol |
General | |
---|---|
Successor | EM10CR |
Mag. Range | 100x, 1000x - 500Kx |
Mag. Gauge | 7-Seg. Digital |
Chamber Pressure | 5*10⁻⁷ Torr |
Power Requirment | 3.5 KVA |
System Weight | 800 Kg |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Acellerating Voltage | 20, 40, 60, 80, 100 KV |
Stability | 2*10⁻⁶min |
Cathode | Tungsten Hairpin |
Cathode Heating | DC |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Nu. of Lenses | 2 |
Stability | 5*10⁻⁶/min |
Stigmator | Quadropol |
Stage | |
---|---|
Holder Type | Cartridge, Top Entery |
Objective | |
---|---|
Lens Type | Electromagnetic |
Focal Length | 2.6mm |
Stability | 2*10⁻⁶/min |
Stigmator | Octopol |
Spherical Error | 2.2 mm |
Chromatic Error | 1.7 mm |
Resolution | 3Å |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
No. of Lenses | 2 |
Stability | 2*10⁻⁶/min |
Configuration | Single Polpiece |
Stigmator | Octopol |
General | |
---|---|
Mag. Range | 150x, 1100x, 3000x, 20Kx, 30Kx, 250Kx, 400Kx |
Mag. Gauge | 7-Seg. Digital |
Chamber Pressure | 2*10⁻⁶ Torr |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Acellerating Voltage | 50, 80 KV |
Stability | 8*10⁻⁶min |
Cathode | Tungsten Hairpin |
Cathode Heating | DC |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Nu. of Lenses | 2 |
Stability | 6*10⁻⁶/min |
Stigmator | Quadropol |
Spot Size | 3 µm |
Stage | |
---|---|
Holder Type | Cartridge, Top Entery |
Objective | |
---|---|
Lens Type | Electromagnetic |
Focal Length | 2.6mm |
Stability | 4*10⁻⁶/min |
Stigmator | Octopol |
Spherical Error | 2.2 mm |
Chromatic Error | 1.7 mm |
Resolution | 5Å |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
No. of Lenses | 3 |
Stability | 6*10⁻⁶/min |
Configuration | Single Polpiece |
Stigmator | Octopol |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Cathode | Tungsten Hairpin |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Objective | |
---|---|
Lens Type | Electromagnetic |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
Electron Source | |
---|---|
Accelerator Type | Self Biased Triode |
Cathode | Tungsten Hairpin |
Condenser | |
---|---|
Lens Type | Electromagnetic |
Objective | |
---|---|
Lens Type | Electromagnetic |
Projective Lens | |
---|---|
Lens Type | Electromagnetic |
Documentation
Full list of all documents related to the Zeiss Electron Microscopes.
Transmission Electron Microscope
Scanning Electron Microscope
Miscilanious
List of Scanning Electron Microscopes
Pre Cambridge Acquisition Models
Model | Year |
---|---|
DSM950 | |
DSM940 | |
DSM940A | |
DSM960 | |
DSM962 |
Post Cambridge Acquisition Models
stuff
Transmission Electron Microscops | |||||||||
---|---|---|---|---|---|---|---|---|---|
Model | Year | Accelerating Voltage | Cathode Type | Nr. of Condensor Lenses | Nr. of Imaging Lenses | Projective | Resolution | Successor | |
EM7 | EM8 | ||||||||
EM8 | Tungsten Hairpin | 1 Electrostatic | 3 Electrostatic | Imersion and EinzelLense | EM9 | ||||
EM9 | 60 KV | Tungsten Hairpin | 1 Electromagnetic | 3 Electromagnetic | Single Polpiece | 70 Å [1] | [[EM10}] | ||
EM10 | 20, 40, 60, 80, 100 KV | 2 Electromagnetic | 3 Electromagnetic | Single Polpiece | < 30 Å [2] | EM900 | |||
EM109 | 50, 80 KV | Tungsten Hairpin | 2 Electromagnetic | 4 Electromagnetic | Single Polpiece | 50 Å [3] | |||
EM900 | Tungsten Hairpin | EM902 | |||||||
EM902 | Tungsten Hairpin | EM912 | |||||||
EM906 | Tungsten Hairpin | Single Polpiece | |||||||
EM910 | Tungsten Hairpin | ||||||||
EM912 | Tungsten Hairpin |