The [https://en.wikipedia.org/wiki/Siemens Siemens Corperation]  has, throughout the years produced many things, among them was the very First [[Electron Microsocpe]]. The history of the Electron Microscope started with Siemenes and Ernst Ruska, together with his research team, they created the very first Electron Microscopes.
The [https://en.wikipedia.org/wiki/Siemens Siemens Corperation]  has, throughout the years produced many things, among them was the very First [[Electron Microsocpe]]. The history of the Electron Microscope started with Siemenes and Ernst Ruska, together with his research team, they created the very first Electron Microscopes.
= Timeline =
<itimeline>
1939-01-01/1949-01-01|Universal|Übermikroskop
1949-01-01/1955-01-01|Universal|[[ÜM100]]
1954-01-01/1961-01-01|Universal|[[Elmiskop I]]
1961-01-01/1971-01-01|Universal|[[Elmiskop IA]]
1968-01-01/1971-01-01|Universal|[[Elmiskop 101]]
1971-01-01/1978-01-01|Universal|[[Elmiskop 102]]
1977-01-01/1978-01-01|Universal|[[Elmiskop CT150]]
1961-01-01/1971-01-01|EPMA|[[Elmisonde]]
1977-01-01/1978-01-01|STEM|[[Elmiskop ST100F]]
1949-01-01/1955-01-01|Budget|[[ÜM60]]
1955-01-01/1956-01-01|Budget|[[Elmiskop II]]
1956-01-01/1971-01-01|Budget|[[Elmiskop 51]]
1938-01-01|Experimental|Prototyp 1
1938-05-01|Experimental|Prototyp 2
1954-01-01|Experimental|Elmiskop II Prototype
1956-01-01|Experimental|Elmiskop 51 Prototype
</itimeline>




= Models =
= Models =
Siemens, as the company responsible for the invention of the Electron Microscope has produced many models throughout the years, also selling a rebadged version of the [[ETEC Autoscan| Etec Autoscan]] which was sold under the Siemens name outside the United States. Most of their models however where of the Transmission kind, mostly due to Ernst Ruskas Prescience.  
Siemens, as the company responsible for the invention of the Electron Microscope has produced many models throughout the years, also selling a rebadged version of the [[ETEC Autoscan| Etec Autoscan]] which was sold under the Siemens name outside the United States. Most of their models however where of the Transmission kind, mostly due to Ernst Ruskas Prescience.  
==Transmission Electron Microscops new ==
==Transmission Electron Microscops==
test
{{#DeviceInfoBox2:tem|Prototyp 1|File:Siemens - Prototyp.png|
{{#DeviceInfoBox2:tem|Prototyp 1|File:Siemens - Prototyp.png|
OEM=File:Siemens & Halske - Logo - 1971.png;
OEM=File:Siemens & Halske - Logo - 1971.png;
Line 63: Line 87:
proj_no=1;
proj_no=1;
holder=Cartridge, Top Entery;
holder=Cartridge, Top Entery;
chamber=10e-4 Torr;
chamber=1·10⁻⁴ Torr;
|}}
 
{{#DeviceInfoBox2:tem|ÜM60||
OEM=File:Siemens & Halske - Logo - 1971.png;
year=1950;
successor=Elmiskop II;
accel=Self Biased Triode;
accel_volt=40, 50, 60 KV;
cath_type=Tungsten Hairpin;
conl_type=Electromagnetic;
objl_type=Electromagnetic;
proj_type=Electromagnetic;
proj_no=1;
holder=Cartridge, Top Entery;
 
|}}
|}}


Line 73: Line 112:
power=3.3 KVA;
power=3.3 KVA;
weight=1200 Kg;
weight=1200 Kg;
accel_stab=2*10⁻⁵/min;
accel_stab=2·10⁻⁵⁄ₘᵢₙ;
cath_heat=AC;
cath_heat=AC;
successor=Elmiskop IA;
successor=Elmiskop IA;
Line 81: Line 120:
conl_type=Electromagnetic;
conl_type=Electromagnetic;
conl_no=2;
conl_no=2;
conl_stab=10⁻³/min;
conl_stab=1·10⁻³⁄ₘᵢₙ;
conl_stig=Moveing Iron;
conl_stig=Moveing Iron;
conl_spot=2µm;
conl_spot=2µm;
Line 87: Line 126:
objl_foc=2.8mm;
objl_foc=2.8mm;
objl_range=2.8mm to 7.4mm;
objl_range=2.8mm to 7.4mm;
objl_stab=10⁻⁵/min;
objl_stab=1·10⁻⁵⁄ₘᵢₙ;
objl_res=5Å;
objl_res=5Å;
objl_type=Electromagnetic;
objl_type=Electromagnetic;
proj_type=Electromagnetic;
proj_type=Electromagnetic;
proj_no=2;
proj_no=2;
proj_stab=10⁻⁴/min;
proj_stab=1·10⁻⁴⁄ₘᵢₙ;
proj_conf=4 Polpiece Revolver;
proj_conf=4 Polpiece Revolver;
proj_mag=12.5:1, 31.2:1, 62.5:1, 125:1, 250:1;
proj_mag=12.5:1, 31.2:1, 62.5:1, 125:1, 250:1;
holder=Cartridge, Top Entery;
holder=Cartridge, Top Entery;
chamber=10e-4 Torr;
chamber=1·10⁻⁴ Torr;
objl_spher=3.3 mm;
|
|
{{#tree:
{{#tree:
Line 136: Line 176:
}}
}}


[[Category:Pages using DynamicPageList parser function]]
{{#DeviceInfoBox2:tem|Elmiskop II Protoype|File:Siemens - Elmiskop II Prototype.png|
OEM=File:Siemens & Halske - Logo - 1971.png;
year=1954;
successor=Elmiskop II;
accel=Self Biased Steigerwald Triode;
accel_volt=40, 50, 60 KV;
cath_type=Tungsten Hairpin;
objl_type=Electromagnetic;
proj_type=Electromagnetic;
proj_no=1;
holder=Cartridge, Top Entery;
objl_stab=3·10⁻⁵⁄ₘᵢₙ;
objl_res=25Å;
proj_conf=4 Polpiece Revolver;
|}}
 


== Transmission Electron Microscops  ==
 
{| class="wikitable"
 
! scope="row" colspan="9" style="text-align:left;"|[[High Speed Oscillograph Electron Source]]
 
|-style="vertical-align:top;"
 
|style="text-align:center;vertical-align:middle;"|[[File:Ruska Prototype 1 - meek.jpg|200px|link=High Speed Oscillograph Electron Source]]
{{#DeviceInfoBox2:tem|Elmiskop II|File:Siemens - Elmiskop II - Column 2.png|
|style="text-align:center;"|
OEM=File:Siemens & Halske - Logo - 1971.png;
{| class="wikitable"
year=1955;
! scope="row" colspan="2"|General
successor=Elmiskop 51;
|-
accel=Self Biased Steigerwald Triode;
! scope="row"|Year
accel_volt=50 KV;
|style="text-align:center;"| 1933
accel_stab=5·10⁻⁵⁄ₘᵢₙ;
|-
cath_type=Tungsten Hairpin;
! scope="row"|Successor
objl_type=Electromagnetic;
|style="text-align:center;"| [[Prototype 1]]
proj_type=Electromagnetic;
|-
proj_no=1;
! scope="row"|Magnification Range
holder=Cartridge, Top Entery;
|style="text-align:center;"| N/A
power=2 KVA;
|-
weight=700 Kg;
! scope="row"|Magnification Gauge Type
objl_foc=1.8mm;
|style="text-align:center;"| N/A
objl_range=2.8mm to 7.4mm;
|-
objl_stab=3·10⁻⁵⁄ₘᵢₙ;
! scope="row"|Specemin Chamber Pressure
objl_res=15Å;
|style="text-align:center;"|10⁻3 Torr
proj_conf=4 Polpiece Revolver;
|-
proj_mag=16.9:1, 69.9:1, 146:1, 300:1;
! scope="row"|Power Consumption
conl_stig=Moveing Iron;
|style="text-align:center;"|
mag_range=295x, 1925x, 8Kx, 17Kx, 35Kx;
|-
chamber=1·10⁻⁴Torr;
! scope="row"|System Weight
|}}
|style="text-align:center;"|
 
|}
{{#DeviceInfoBox2:tem|Elmiskop 51|File:Elmiskop51-overview-meek.jpg|
|style="text-align:center;"|
OEM=File:Siemens & Halske - Logo - 1971.png;
{| class="wikitable"
year=1956;
! scope="row" colspan="2"|Electrion Source
accel=Self Biased Steigerwald Triode;
|-
accel_volt=50 KV;
! scope="row"| Accelerator Type
accel_stab=5·10⁻⁵⁄ₘᵢₙ;
|style="text-align:center;"|[[Kanalstrahlrohr]]
cath_type=Tungsten Hairpin;
|-
objl_type=Permanent Magnet;
! scope="row"| Cathode Type
proj_type=Permanent Magnet;
|style="text-align:center;"|[[Gas Discharge]]
proj_no=1;
|-
objl_res=25-50Å;
! scope="row"| Accelerating Voltage
proj_conf=4 Polpiece Revolver;
|style="text-align:center;"|75 KV
conl_stig=Moveing Iron;
|-
|}}
! scope="row"|Stability
 
|style="text-align:center;"|
{{#DeviceInfoBox2:tem|Elmiskop IA|File:Siemens-Elmiskop-IA.jpg|
|-
OEM=File:Siemens & Halske - Logo - 1971.png;
! scope="row"|Cathode Heating Methode
year=1961;
|style="text-align:center;"|N/A
mag_range=200x - 200Kx;
|-
mag_gauge=Galvanometer;
! scope="row"|Alignment Methode
power=3.3 KVA;
|style="text-align:center;"|
weight=1200 Kg;
|}
accel_stab=2·10⁻⁵⁄ₘᵢₙ;
|style="text-align:center;"|
cath_heat=AC;
{| class="wikitable"
successor=Elmiskop 101;
! scope="row" colspan="2"|Condensor
accel=Self Biased Triode;
|-
accel_volt=40, 60, 80, 100 KV;
! scope="row"|Number of Condensor Lenses
cath_type=Tungsten Hairpin;
|style="text-align:center;"|2
conl_type=Electromagnetic;
|-
conl_no=2;
! scope="row"|Current Stability
conl_stab=1·10⁻³⁄ₘᵢₙ;
|style="text-align:center;"|
conl_stig=Moveing Iron;
|-
conl_spot=2µm;
! scope="row"|Stigmator
xy=± 0.8 mm;
|style="text-align:center;"| N/A
objl_foc=2.8mm;
|-
objl_range=2.8mm to 7.4mm;
! scope="row"|Minimum Spot Size Diameter
objl_stab=1·10⁻⁵⁄ₘᵢₙ;
|style="text-align:center;"|
objl_res=5Å;
|-
objl_type=Electromagnetic;
! scope="row"|Condensor Alignment
proj_type=Electromagnetic;
|style="text-align:center;"|
proj_no=2;
|-
proj_stab=1·10⁻⁴⁄ₘᵢₙ;
! scope="row"|Lens Type
proj_conf=4 Polpiece Revolver;
|style="text-align:center;"|Electromagnetic
proj_mag=12.5:1, 31.2:1, 62.5:1, 125:1, 250:1;
|-
holder=Cartridge, Top Entery;
|}
chamber=1·10⁻⁴Torr;
|style="text-align:center;"|
objl_spher=3.3 mm;
{| class="wikitable"
|
! scope="row" colspan="2"|Stage
}}
|-
 
! scope="row"|Holder Type
{{#DeviceInfoBox2:tem|Elmiskop 101|File:Siemens Elmiskop-101-PLI.jpg|
|style="text-align:center;"|Cartridge, Top Entry
OEM=File:Siemens & Halske - Logo - 1971.png;
|-
year=1968;
! scope="row"|X, Y Travel Range
mag_range=285x - 260Kx;
|style="text-align:center;"| N/A
mag_gauge=Galvanometer;
|}
successor=Elmiskop 102;
accel=Self Biased Triode;
accel_volt=40, 60, 80, 100, 125 KV;
cath_type=Tungsten Hairpin;
conl_type=Electromagnetic;
conl_no=2;
conl_stig=Electromagnetic Octopol;
xy=± 0.8 mm;
objl_type=Electromagnetic;
proj_type=Electromagnetic;
proj_no=2;
proj_conf=2 Polpiece Revolver;
holder=Cartridge, Top Entery;
|}}
 
{{#DeviceInfoBox2:tem|Elmiskop 102|Siemens-elmiskop102 from-brochure.png|
OEM=File:Siemens & Halske - Logo - 1971.png;
year=1972;
mag_range=200x - 500Kx;
mag_gauge=Digital;
power=4 KVA;
weight= Kg;
accel_stab=2·10⁻⁶⁄ₘᵢₙ;
cath_heat=DC;
successor=Elmiskop 103;
accel=Self Biased Triode;
accel_volt=20, 40, 60, 80, 100, 125 KV;
cath_type=Tungsten Hairpin, Tungsten Lancet;
conl_type=Electromagnetic;
conl_no=2;
conl_stab=5·10⁻⁶⁄ₘᵢₙ;
conl_stig=Electromagnetic Octopol;
conl_spot=1.7µm / 0.5 µm;
xy=± 1 mm;
objl_foc=2.7mm;
objl_range=1.6mm (20KV) to 7mm;
objl_stab=< 2·10⁻⁶⁄ₘᵢₙ;
objl_res=3Å;
objl_type=Electromagnetic;
proj_type=Electromagnetic;
proj_no=3;
proj_stab=<5·10⁻⁶⁄ₘᵢₙ;
proj_conf=Single Polpiece;
holder=Cartridge, Top Entery;
chamber=5·10⁻⁶ Torr;
objl_spher=2.9 mm;
objl_chrom=2.1 mm;
successor=Elmiskop CT150;
|
}}
{{#DeviceInfoBox2:tem|Elmiskop CT150|Simens-Elmiskop-ct150-from-brochure.jpg|
OEM=File:Siemens & Halske - Logo - 1971.png;
year=1977;
mag_gauge=Digital;
mag_range=500x - 1200Kx;
accel=Self Biased Triode;
accel_volt=20, 40, 60, 80, 100, 125, 150 KV;
accel_current=100nA → 100µA;
power=5.5kVA;
weight= 1800Kg;
accel_stab=2·10⁻⁶⁄ₘᵢₙ;
cath_heat=DC;
cath_type=Tungsten Hairpin, Tungsten Lancet;
conl_type=Electromagnetic;
conl_no=2;
conl_stab=<5·10⁻⁶⁄ₘᵢₙ;
conl_stig=Electromagnetic Octopol;
conl_spot=500 nm / 200 nm;
holder=Side Entry;
chamber=5·10⁻⁶ Torr;
objl_spher=1.4 mm;
objl_chrom=1.3 mm;
objl_foc=1.7mm;
objl_type=Electromagnetic;
objl_stab=< 2·10⁻⁷⁄ₘᵢₙ;
objl_res=3Å;
proj_type=Electromagnetic;
proj_no=3;
proj_stab=<5·10⁻⁶⁄ₘᵢₙ;
proj_conf=Single Polpiece;
|
}}
{{#DeviceInfoBox2:tem|Elmiskop CT100||
OEM=File:Siemens & Halske - Logo - 1971.png;
year=1977;
mag_gauge=Digital;
accel=Self Biased Triode;
accel_volt=20, 40, 60, 80, 100 KV ?;
|
}}
</br>
<div>~</div>
 
[[Category:Pages using DynamicPageList parser function]]
 
== Scanning Transmission Electron Microscops ==
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop ST100F]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Elmiskop ST100F Overview - annotated.jpg|200px|link=Elmiskop ST100F]]
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
! scope="row" colspan="2"|General
|-
|-
! scope="row"|Focal Length
! scope="row"|Year
|style="text-align:center;"| N/A
|style="text-align:center;"| 1977
|-
|-
! scope="row"|Adjustment Range
! scope="row"|Successor
|style="text-align:center;"| N/A
|style="text-align:center;"| none
|-
|-
! scope="row"|Spherical Error
! scope="row"|Magnification Range
|style="text-align:center;"|N/A
|style="text-align:center;"| 50x - 10e7X
|-
|-
! scope="row"|Current Stability
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|N/A
|style="text-align:center;"|
|-
|-
! scope="row"|Stigmator
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|N/A
|style="text-align:center;"|10e-7 mBar
|-
|-
! scope="row"|Alignment Aids
! scope="row"|Power Consumption
|style="text-align:center;"|N/A
|style="text-align:center;"|  
|-
|-
! scope="row"|Point Resolution
! scope="row"|System Weight
|style="text-align:center;"|N/A
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
|-
! scope="row"|Lens Type
! scope="row"| Accelerator Type
|style="text-align:center;"|N/A
|style="text-align:center;"|[[Crewe FE Electron Gun]]
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
|-
! scope="row"|Number of Projective Lens
! scope="row"| Cathode Type
|style="text-align:center;"|N/A
|style="text-align:center;"|[[Cold Field Emmision]]
|-
|-
! scope="row"|Current Stability
! scope="row"| Accelerating Voltage
|style="text-align:center;"|N/A
|style="text-align:center;"|20, 40, 60, 80, 100 KV, (10 - 30 KV)
|-
|-
! scope="row"|Polpeace Configuration
! scope="row"|Stability
|style="text-align:center;"|N/A
|style="text-align:center;"|2*10e-6
|-
|-
! scope="row"|Avalible Polpeace Magnifications
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|N/A
|style="text-align:center;"|N/A
|-
|-
! scope="row"|Alignment
! scope="row"|Alignment Methode
|style="text-align:center;"|N/A
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
|-
! scope="row"|Lens Type
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|N/A
|style="text-align:center;"|1
|}
|-
|}
! scope="row"|Current Stability
 
|style="text-align:center;"|2*10e-6
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Prototyp 1]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Ruska Prototype 2 - meek.jpg|200px|link=Prototyp 1]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
|-
! scope="row"|Year
! scope="row"|Stigmator
|style="text-align:center;"| 1933
|style="text-align:center;"|
|-
|-
! scope="row"|Successor
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"| [[Prototype 2]]
|style="text-align:center;"|
|-
|-
! scope="row"|Magnification Range
! scope="row"|Condensor Alignment
|style="text-align:center;"|  
|style="text-align:center;"|
|-
|-
! scope="row"|Magnification Gauge Type
! scope="row"|Lens Type
|style="text-align:center;"|  
|style="text-align:center;"|Crewe Electrostatic
|-
|-
! scope="row"|Specemin Chamber Pressure
|}
|style="text-align:center;"|10⁻3 Torr
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
|-
! scope="row"|Power Consumption
! scope="row"|Holder Type
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|System Weight
! scope="row"|X, Y Travel Range
|style="text-align:center;"|
|style="text-align:center;"|+- 1 mm
|}
|}
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
! scope="row" colspan="2"|Objective Lens
|-
|-
! scope="row"| Accelerator Type
! scope="row"|Focal Length
|style="text-align:center;"|[[Kanalstrahlrohr]]
|style="text-align:center;"| 1.8 mm
|-
|-
! scope="row"| Cathode Type
! scope="row"|Adjustment Range
|style="text-align:center;"|[[Gas Discharge]]
|style="text-align:center;"|  
|-
|-
! scope="row"| Accelerating Voltage
! scope="row"|Spherical Error
|style="text-align:center;"|75 KV
|style="text-align:center;"|1.3 mm
|-
|-
! scope="row"|Stability
! scope="row"|Chromatic Error
|style="text-align:center;"|
|style="text-align:center;"|1.3 mm
|-
|-
! scope="row"|Cathode Heating Methode
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|style="text-align:center;"| 1 * 10e-6
|-
|-
! scope="row"|Alignment Methode
! scope="row"|Stigmator
|style="text-align:center;"|Electromagnetic
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|style="text-align:center;"|
|}
|-
! scope="row"|Point Resolution
|style="text-align:center;"|2 [https://en.wikipedia.org/wiki/Angstrom Å]
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|Condensor
! scope="row" colspan="2"|Projective Lens
|-
|-
! scope="row"|Number of Condensor Lenses
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|style="text-align:center;"|
|-
|-
! scope="row"|Current Stability
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Stigmator
! scope="row"|Polpeace Configuration
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Minimum Spot Size Diameter
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|  
|style="text-align:center;"|
|-
|-
! scope="row"|Condensor Alignment
! scope="row"|Alignment
|style="text-align:center;"|  
|style="text-align:center;"|
|-
|-
! scope="row"|Lens Type
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|style="text-align:center;"|
|-
|}
|}
|}
 
 
 
== X-Ray Micro Analyzers ==
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmisonde]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Elmisonde - Overview from Brochure.jpg|200px|link=Elmisonde]]
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|Stage
! scope="row" colspan="2"|General
|-
|-
! scope="row"|Holder Type
! scope="row"|Year
|style="text-align:center;"|Cartridge, Top Entry
|style="text-align:center;"| 1961
|-
|-
! scope="row"|X, Y Travel Range
! scope="row"|Successor
|style="text-align:center;"| N/A
|style="text-align:center;"| none
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
|-
! scope="row"|Focal Length
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|  
|style="text-align:center;"|  
|-
|-
! scope="row"|Spherical Error
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Current Stability
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Stigmator
! scope="row"|Power Consumption
|style="text-align:center;"|
|style="text-align:center;"|  
|-
|-
! scope="row"|Alignment Aids
! scope="row"|System Weight
|style="text-align:center;"|
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
|-
! scope="row"|Point Resolution
! scope="row"| Accelerator Type
|style="text-align:center;"|500 [https://en.wikipedia.org/wiki/Angstrom Å] <ref>Geoffrey A. Meek, Practical Electron Microscopy for the Biologist, 2nd Edition (1976), Page 57</ref>
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
|-
! scope="row"|Lens Type
! scope="row"| Cathode Type
|style="text-align:center;"|Electromagnetic
|style="text-align:center;"|[[Tungsten Hairpin]]
|}
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 60, 80, 100 KV
|-
! scope="row"|Stability
|style="text-align:center;"|2*10⁻⁵/min
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
! scope="row" colspan="2"|Condensor
|-
|-
! scope="row"|Number of Projective Lens
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|1
|style="text-align:center;"|2
|-
|-
! scope="row"|Current Stability
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Polpeace Configuration
! scope="row"|Stigmator
|style="text-align:center;"|Single Polpiece
|style="text-align:center;"|Moveing Iron, Mechanical
|-
|-
! scope="row"|Avalible Polpeace Magnifications
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Alignment
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|style="text-align:center;"|X, Y, and Tilt, Mechanical
|-
|-
! scope="row"|Lens Type
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|style="text-align:center;"|Electromagnetic
|}
|-
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Prototyp 2]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Prototyp.png|200px|link=Prototyp 2]]
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|General
! scope="row" colspan="2"|Stage
|-
|-
! scope="row"|Year
! scope="row"|Holder Type
|style="text-align:center;"| 1938
|style="text-align:center;"|Cartridge, Top Entry
|-
|-
! scope="row"|Successor
! scope="row"|X, Y Travel Range
|style="text-align:center;"| [[Prototype 3]]
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
|-
! scope="row"|Magnification Range
! scope="row"|Focal Length
|style="text-align:center;"|  
|style="text-align:center;"|
|-
|-
! scope="row"|Magnification Gauge Type
! scope="row"|Adjustment Range
|style="text-align:center;"|  
|style="text-align:center;"|  
|-
|-
! scope="row"|Specemin Chamber Pressure
! scope="row"|Spherical Error
|style="text-align:center;"|10⁻3 Torr?
|style="text-align:center;"|
|-
|-
! scope="row"|Power Consumption
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|System Weight
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
|-
! scope="row"| Accelerator Type
! scope="row"|Point Resolution
|style="text-align:center;"|[[Kanalstrahlrohr]]
|style="text-align:center;"|
|-
|-
! scope="row"| Cathode Type
! scope="row"|Lens Type
|style="text-align:center;"|[[Gas Discharge]]
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
|-
! scope="row"| Accelerating Voltage
! scope="row"|Number of Projective Lens
|style="text-align:center;"|75 KV?
|style="text-align:center;"|1
|-
|-
! scope="row"|Stability  
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Cathode Heating Methode
! scope="row"|Polpeace Configuration
|style="text-align:center;"|N/A
|style="text-align:center;"|4 Position Revolver
|-
|-
! scope="row"|Alignment Methode
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
|-
! scope="row"|Number of Condensor Lenses
! scope="row"|Alignment
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
|-
! scope="row"|Lens Type
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|style="text-align:center;"|Electromagnetic
|-
|}
|}
|}
|style="text-align:center;"|
{| class="wikitable"
== Scanning Electron Microscops ==
! scope="row" colspan="2"|Stage
|-
{| class="wikitable"
! scope="row"|Holder Type
! scope="row" colspan="9" style="text-align:left;"|[[ETEC Autoscan| Autoscan]]
|style="text-align:center;"|Cartridge, Top Entry
|-style="vertical-align:top;"
|-
|style="text-align:center;vertical-align:middle;"|[[File:Autoscan Column.jpg|200px|link=ETEC Autoscan]]
! scope="row"|X, Y Travel Range
|style="text-align:center;"| N/A
|}
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
! scope="row" colspan="2"|General
|-
|-
! scope="row"|Focal Length
! scope="row"|Year
|style="text-align:center;"|
|style="text-align:center;"| 1972
|-
|-
! scope="row"|Adjustment Range
! scope="row"|Successor
|style="text-align:center;"|  
|style="text-align:center;"| none
|-
|-
! scope="row"|Spherical Error
! scope="row"|Magnification Range
|style="text-align:center;"|
|style="text-align:center;"| 20 - 550Kx
|-
|-
! scope="row"|Current Stability
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|style="text-align:center;"| Analog, (Digital)
|-
|-
! scope="row"|Stigmator
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|style="text-align:center;"| 2 * 10-4 Torr
|-
|-
! scope="row"|Alignment Aids
! scope="row"|Power Consumption
|style="text-align:center;"|
|style="text-align:center;"| 3 KVA
|-
|-
! scope="row"|Point Resolution
! scope="row"|System Weight
|style="text-align:center;"|
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
|-
! scope="row"|Lens Type
! scope="row"| Accelerator Type
|style="text-align:center;"|Electromagnetic
|style="text-align:center;"|Single Stage [[Electron Gun]]
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
|-
! scope="row"|Number of Projective Lens
! scope="row"| Cathode Type
|style="text-align:center;"|1
|style="text-align:center;"|[[Tungsten Hairpin]] / [[LaB6]] / [[Field Emission?]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|2.5, 5, 10, 20, 30, (50) KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|HF
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|3
|-
|-
! scope="row"|Current Stability
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Polpeace Configuration
! scope="row"|Stigmator
|style="text-align:center;"|Single Polpiece
|style="text-align:center;"|none
|-
|-
! scope="row"|Avalible Polpeace Magnifications
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Alignment
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|style="text-align:center;"|none, prealigned
|-
|-
! scope="row"|Lens Type
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|style="text-align:center;"|3 gap Common Coil Electromagnetic
|}
|-
|}
|}
 
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Prototyp 3]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Ruska Prototype 3 - meek.jpg|200px|link=Prototyp 2]]
|style="text-align:center;"|
|style="text-align:center;"|
{| class="wikitable"
{| class="wikitable"
! scope="row" colspan="2"|General
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|
|-
|-
! scope="row"|Year
! scope="row"|X, Y Travel Range
|style="text-align:center;"| 1938
|style="text-align:center;"|+- 12.5 mm
|-
|-
! scope="row"|Successor
! scope="row"|Z Travel Range
|style="text-align:center;"| [[Übermikroskop]]
|style="text-align:center;"|25 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
|-
! scope="row"|Magnification Range
! scope="row"|Focal Length
|style="text-align:center;"|  
|style="text-align:center;"|  
|-
|-
! scope="row"|Magnification Gauge Type
! scope="row"|Adjustment Range
|style="text-align:center;"|  
|style="text-align:center;"|  
|-
|-
! scope="row"|Specemin Chamber Pressure
! scope="row"|Spherical Error
|style="text-align:center;"|10⁻3 Torr?
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|System Weight
! scope="row"|Current Stability
|style="text-align:center;"|
|style="text-align:center;"|  
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
|-
! scope="row"| Accelerator Type
! scope="row"|Stigmator
|style="text-align:center;"|[[Kanalstrahlrohr]]
|style="text-align:center;"| Dual Quadropol Electromagnetic
|-
|-
! scope="row"| Cathode Type
! scope="row"|Alignment Aids
|style="text-align:center;"|[[Gas Discharge]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|75 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|style="text-align:center;"|
|-
|-
! scope="row"|Cathode Heating Methode
! scope="row"|Point Resolution
|style="text-align:center;"|N/A
|style="text-align:center;"|7 nm
|-
|-
! scope="row"|Alignment Methode
! scope="row"|Lens Type
|style="text-align:center;"|
|style="text-align:center;"|Electromagnetic
|}
|}
|style="text-align:center;"|
|}
{| class="wikitable"
 
! scope="row" colspan="2"|Condensor
 
|-
 
! scope="row"|Number of Condensor Lenses
= Documentation =
|style="text-align:center;"|1
Full list of all documents related to the Siemens Electron Microscopes.
|-
{{#tree:
! scope="row"|Current Stability
*[[Elmiskop I]]
|style="text-align:center;"|
**Service
|-
***{"icon":false}{{#l:Siemens - C70389-A2101-S116 - EO-ÜM2101-Bp7 - Stativ Bauschaltplan.pdf|C70389-A2101-S116 - EO-ÜM2101-Bp7 - Stativ Bauschaltplan}}
! scope="row"|Stigmator
***{"icon":false}{{#l:Siemens - C70389-A11-5734 - Eo ÜM11 Zb34 - Umbau des Elmiskop I-Geräts ab F Fr 288 (7 Ordner) in Geräte mit normaler und langer Brennweite.pdf|C70389-A11-5734 - Eo ÜM11 Zb34 - Umbau des Elmiskop I-Geräts ab F Fr 288 (7 Ordner) in Geräte mit normaler und langer Brennweite}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - C70389-A11-S7 8 - Eo ÜM11 SK7 - Schaltteilliste zum Elmiskop I.pdf|C70389-A11-S7 8 - Eo ÜM11 SK7 - Schaltteilliste zum Elmiskop I}}
|-
***{"icon":false}{{#l:Siemens - C70144-A154-S6 10 - EO div 154 Sk6 - Netzanschlusschrank für Elmiskop I Sammelkarte.pdf|C70144-A154-S6 10 - EO div 154 Sk6 - Netzanschlusschrank für Elmiskop I Sammelkarte}}
! scope="row"|Minimum Spot Size Diameter
***{"icon":false}{{#l:Siemens - C70392-B8001-S2 - Eo verst 1 SK 2 - Linsenstrom-Regler Sammelkarte.pdf|C70392-B8001-S2 - Eo verst 1 SK 2 - Linsenstrom-Regler Sammelkarte}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - C70280-A1-S3 - Eo na1 SK3 - Linsenstrom-Netzgerät Sammelkarte.pdf|C70280-A1-S3 - Eo na1 SK3 - Linsenstrom-Netzgerät Sammelkarte}}
|-
***{"icon":false}{{#l:Siemens - C70392-B8002-S1 - EO verst 2 Sk1 - Hochspannungsregler Sammelkarte.pdf|C70392-B8002-S1 - EO verst 2 Sk1 - Hochspannungsregler Sammelkarte}}
! scope="row"|Condensor Alignment
***{"icon":false}{{#l:Siemens - C70144-A148-S4 - EO div 148 SK4 - 100 kV-Gleichrichter Sammelkarte.pdf|C70144-A148-S4 - EO div 148 SK4 - 100 kV-Gleichrichter Sammelkarte}}
|style="text-align:center;"|
 
|-
***{"icon":false}{{#l:Siemens - C71122-A3-A1.pdf| C71122-A3-A1 - Batteriekasten}}
! scope="row"|Lens Type
***{"icon":false}{{#l:Siemens - Eo verst 2 SK 1.pdf|C70392-B8002-S1 - Eo verst 2 SK 1 - Hochspannungsregler Sammelkarte}}
|style="text-align:center;"|Electromagnetic
 
|-
***{"icon":false}{{#l:Siemens - C71280-A3-A1-A2.pdf|C71280-A3-A1-A2 - Netzanschlußschrank Elmiskop I}}
|}
***{"icon":false}{{#l:Siemens - C71280-A3-B2 B3.pdf|C71280-A3-B2 B3 - Luftschützplatte}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - C71280-A3-B1.pdf|C71280-A3-B1 - Kondensator- und Widerstandsplatte}}
{| class="wikitable"
***{"icon":false}{{#l:Siemens - C71302-A3-A1 A2.pdf|C71302-A3-A1 A2 - Linsenstrom-Regler}}
! scope="row" colspan="2"|Stage
***{"icon":false}{{#l:Siemens - C71302-A3-B2.pdf|C71302-A3-B2 - Chassis I}}
|-
***{"icon":false}{{#l:Siemens - C71302-A3-B9.pdf|C71302-A3-B9 - Winkel mit Relaisfassung}}
! scope="row"|Holder Type
***{"icon":false}{{#l:Siemens - C71302-A3-B10.pdf|C71302-A3-B10 - Chassis II}}
|style="text-align:center;"|Cartridge, Top Entry
***{"icon":false}{{#l:Siemens - C71302-A3-B16.pdf|C71302-A3-B16 - Frontplatte, kpl.}}
|-
***{"icon":false}{{#l:Siemens - C71302-A3-B19.pdf|C71302-A3-B19 - Schalteraufbau I}}
! scope="row"|X, Y Travel Range
***{"icon":false}{{#l:Siemens - C71302-A3-B24.pdf|C71302-A3-B24 - Schalteraufbau II}}
|style="text-align:center;"| N/A
***{"icon":false}{{#l:Siemens - eg uM 11 k12.pdf|C70389-A11-S12 - Schaltteilliste zum Elmiskop I}}
|}
***{"icon":false}{{#l:Siemens - eg uM 2702 Sk6.pdf|C70389-A2702-S6 - Eo. ÜM 2702 SK6 - Schaltteilliste zum Bedienungskasten für Elmiskop I}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - EO div148 SK4.pdf|C70144-A148-S4 - EO. Div, 148 SK4 - 100 kV-Gleichrichter Sammelkarte}}
{| class="wikitable"
***{"icon":false}{{#l:Siemens - Eo no 1 SK 3.pdf|C70280-A1-S3 - Eo. na 1, Sk3 - Linsenstrom--Netzgerät Sammelkarte}}
! scope="row" colspan="2"|Objective Lens
 
|-
 
! scope="row"|Focal Length
**Promotional
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - 1-7601-203 - Elmikop I - Brochure.pdf|1/7601-203 - Elmikop I - Brochure}}
|-
***{"icon":false}{{#l:Siemens Elmiskop 1 - Grossraum Objektkammer.pdf|Grossraum Objektkammer Brochure}}
! scope="row"|Adjustment Range
***{"icon":false}{{#l:Siemens Elmiskop 1 - Objektheizeinrichtung.pdf|Objektheizeinrichtung Brochure}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens Elmiskop 1 - Objektkühleinrichtung.pdf|Objektkühleinrichtung Brochure}}
|-
***{"icon":false}{{#l:Siemens Elmiskop 1 - Objektraumkühlung.pdf|Objektraumkühlung Brochure}}
! scope="row"|Spherical Error
***{"icon":false}{{#l:Siemens Elmiskop 1 - Bildübertragungseinrichtung.pdf|Bildübertragungseinrichtung Brochure}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - Einrichtung für Außenkinematografie am Elmiskop 1A, 1 und Elmiskop II - comp.pdf|Einrichtung für Außenkinematografie Brochure}}
|-
***{"icon":false}{{#l:Siemens - Einrichtung für Innenkinematographie zum Elmiskop 1, 1A und Elmisop II - comp.pdf|Einrichtung für Innenkinematographie Brochure}}
! scope="row"|Current Stability
***{"icon":false}{{#l:Siemens - 70-mm.Filmkasette für das Elmiskop 1A, 1 und II - comp.pdf|70-mm.Filmkasette Brochure}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - Bildübertragungseinrichtung für Siemens-Elektronenmikroskope - comp.pdf|Bildübertragungseinrichtung Brochure}}
|-
***{"icon":false}{{#l:Siemens - Einrichtung für Objektraumkühlung zum Elmiskop 1 und am Elmiskop 1A - comp.pdf|Einrichtung für Objektraumkühlung Brochure}}
! scope="row"|Stigmator
***{"icon":false}{{#l:Siemens - Spitzenkathode zum Elmiskop IA und Elmiskop I - comp.pdf|Spitzenkathode Brochure}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - Objektkühleinrichtung zum Elmiskop 1A und Elmiskop 1 - comp.pdf|Objektkühleinrichtunge Brochure}}
|-
***{"icon":false}{{#l:Siemens - Objektpatrone für Dehnungsverfahren zum Elmiskop IA und Elmiskop I - comp.pdf|Objektpatrone für Dehnungsverfahren Brochure}}
! scope="row"|Alignment Aids
***{"icon":false}{{#l:Siemens - Elektrischer Belichtungsverschluß zum Elmiskop IA und Elmiskop II - comp.pdf|Elektrischer Belichtungsverschluß Brochure}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - Doppelkipp-Einrichtung für Objekte zum Elmiskop I und IA - comp.pdf|Doppelkipp-Einrichtung Brochure}}
|-
***{"icon":false}{{#l:Siemens - Großraum-Objektkammer zum Elmiskop 1A und Elmiskop 1 - comp.pdf|Großraum-Objektkammer Brochure}}
! scope="row"|Point Resolution
***{"icon":false}{{#l:Siemens - Röntgenspektrometer-Zusatz zum Elmiskop IA und I - comp.pdf|Röntgenspektrometer-Zusatz Brochure}}
|style="text-align:center;"|100 [https://en.wikipedia.org/wiki/Angstrom Å] <ref>Geoffrey A. Meek, Practical Electron Microscopy for the Biologist, 2nd Edition (1976), Page 58</ref>
***{"icon":false}{{#l:Siemens - Objektheizeinrichtung zum Elmiskop IA und Elmiskop I - comp.pdf|Objektheizeinrichtung Brochure}}
|-
***{"icon":false}{{#l:Siemens - Objektpatrone für Reflexionsbeugung zum Elmiskop IA, I und II - comp.pdf|Objektpatrone für Reflexionsbeugung Brochure}}
! scope="row"|Lens Type
***{"icon":false}{{#l:Siemens - Einrichtung für Simultanbeugung zum Elmiskop I und IA - comp.pdf|Einrichtung für Simultanbeugung Brochure}}
|style="text-align:center;"|Electromagnetic
***{"icon":false}{{#l:Siemens - Dünnwandige Objektivaperturblenden für die Elektronenmikroskopie - comp.pdf|Dünnwandige Objektivaperturblenden Brochure}}
|}
***{"icon":false}{{#l:Siemens - Einrichtung für Röntgenmikroanalyse (RMA) zum Elmiskop Ia und Elmiskop I - comp.pdf|Einrichtung für Röntgenmikroanalyse (RMA) Brochure}}
|style="text-align:center;"|
*[[Elmiskop II]]
{| class="wikitable"
**Service
! scope="row" colspan="2"|Projective Lens
***{"icon":false}{{#l:Siemens - C70389-A13-S301 - Eo ÜM 13 str 1 - Elmiskop II Stromlaufplan.pdf|C70389-A13-S301 - Eo ÜM 13 str 1 - Elmiskop II Stromlaufplan}}
|-
*[[Elmiskop IA]]
! scope="row"|Number of Projective Lens
**Manual
|style="text-align:center;"|1
***{"icon":false}{{#l: Siemens-Elmiskop-IA-Band1-Bedienungsanleitung.pdf|Eg1/1000.16/10.64 - Band 1 - Bedienungsanleitung}}
|-
***{"icon":false}{{#l:Siemens - Elmiskop IA - Bedienungsanleitung - Band 2 - Bilder und Pläne.pdf|Eg1/1000.16/10.64 - Band 2 - Bilder und Pläne}}
! scope="row"|Current Stability
***{"icon":false}{{#l:Siemens - Elmiskop 1A - Band 2 - Abbildungen - EN DE.pdf|Eg1/1000.16/10.64e - Band 2 - Bilder und Pläne}}
|style="text-align:center;"|
***{"icon":false}{{#l:Siemens - Elmiskop 1A - Volume 1 - Instruction Manual.pdf|Volume 1 - Instruction Manual}}
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|Single Polpiece
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}  
|}


{| class="wikitable"
*[[Elmiskop 101]]
! scope="row" colspan="9" style="text-align:left;"|[[Übermikroskop]]
**Manual
|-style="vertical-align:top;"
***{"icon":false}{{#l:Siemens - Anleitung EG 1A19 - 1d - Elmiskop 101 Bedienungsanleitung.pdf|EG 1A19 - 1d - Elmiskop 101 Bedienungsanleitung}}
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Übermikroskop - Meek.jpg|200px|link=Übermikroskop]]
***{"icon":false}{{#l:Siemens - MWB EM Q 801def 6 76 - Transportanleitung Elmiskop 101 & 102.pdf|MWB EM Q/801def/6.76 - Transportanleitung Elmiskop 101 & 102}}
|style="text-align:center;"|
 
{| class="wikitable"
*[[Elmiskop 102]]
! scope="row" colspan="2"|General
**Manual
|-
***{"icon":false}{{#l:Siemens - MWB C73000-B3100-C3-1 - Elmiskop 102 Bedienungsanleitung.pdf|MWB C73000-B3100-C3-1 - Elmiskop 102 Bedienungsanleitung}}
! scope="row"|Year
***{"icon":false}{{#l:Siemens - MWB EM Q 801def 6 76 - Transportanleitung Elmiskop 101 & 102.pdf|MWB EM Q/801def/6.76 - Transportanleitung Elmiskop 101 & 102}}
|style="text-align:center;"| 1939
|-
! scope="row"|Successor
|style="text-align:center;"| [[ÜM100]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻4 Torr?
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|[[Kanalstrahlrohr]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Gas Discharge]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|75 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|N/A
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|100 [https://en.wikipedia.org/wiki/Angstrom Å] <ref>Geoffrey A. Meek, Practical Electron Microscopy for the Biologist, 2nd Edition (1976), Page 58</ref>
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|Single Polpiece
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
 
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[ÜM100 Gen1]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1939
|-
! scope="row"|Successor
|style="text-align:center;"| [[ÜM100]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻4 Torr?
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|[[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|55, 70, 85, 100 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|Single Polpiece
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[ÜM100]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - ÜM100 - Ruska 1953.png|200px|link=ÜM100]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1949
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop I]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻4 Torr?
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|[[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 60, 80, 100 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|Single Polpiece
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
 
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[ÜM60]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1950
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop II]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻4 Torr?
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|[[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 50, 60 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|N/A
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|Single Polpiece
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop I]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Elmiskop1-Front-Brochure.jpg|200px|link=Elmiskop 1]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1954
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop IA]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"| 200x to 200,000x
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|Galvanometer
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻⁴ Torr
|-
! scope="row"|Power Consumption
|style="text-align:center;"| 3.3 KVA
|-
! scope="row"|System Weight
|style="text-align:center;"|1200 Kg
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 60, 80, 100 KV
|-
! scope="row"|Stability
|style="text-align:center;"|2*10⁻⁵/min
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|10⁻³/min
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|2000 nm
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|X, Y, and Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"| 2.8mm
|-
! scope="row"|Adjustment Range
|style="text-align:center;"| 2.8mm to 7.4mm
|-
! scope="row"|Spherical Error
|style="text-align:center;"|3.3mm
|-
! scope="row"|Current Stability
|style="text-align:center;"|10⁻⁵/min
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|5 [https://en.wikipedia.org/wiki/Angstrom Å]
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|10⁻⁴/min
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|12.5:1, 31.2:1, 62.5:1, 125:1, 250:1
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop II Prototype]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Elmiskop II Prototype.png|200px|link=Elmiskop II Prototype]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1954
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop II]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|Galvanometer
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻⁴ Torr
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 50, 60 KV 
|-
! scope="row"|Stability
|style="text-align:center;"
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|0
|-
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|X, Y, and Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|3 * 10⁻⁵/min
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|25 [https://en.wikipedia.org/wiki/Angstrom Å] <ref>K. Müller & E. Ruska, Ein vereinfachtest Elektromagnetisches Durschstahlungsmikroskop für Elektronen von 40 bis 60KV*), 1954</ref>
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
 
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop II]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Elmiskop II - Column 2.png|200px|link=Elmiskop II]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1955
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 51]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"| 200x to 200,000x
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻⁴ Torr
|-
! scope="row"|Power Consumption
|style="text-align:center;"| 2 KVA
|-
! scope="row"|System Weight
|style="text-align:center;"|700 Kg
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 50 KV
|-
! scope="row"|Stability
|style="text-align:center;"|5.35*10⁻9/min
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|0
|-
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|X, Y, and Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"| 1.8mm
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|3 * 10⁻⁵/min
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|20 [https://en.wikipedia.org/wiki/Angstrom Å]
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|10⁻⁴/min
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|16.9:1, 69.9:1, 146:1, 300:1
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop 51 Prototyp]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Elmiskop51-prototype-overview.jpg|200px|link=Elmiskop 51 Prototyp]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1956
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 51]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 50 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|0
|-
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry 9 position
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"| N/A
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|50 [https://en.wikipedia.org/wiki/Angstrom Å] <ref>K. Müller & E. Ruska, Ein Hilfselektronenmikroskop für Kurs- und Routinebetrieb, (1956), Vierter Internationaler Kongress für Elektronenmikroskopie, Physikalisch Technischer teil, Page 184-187</ref>
|-
! scope="row"|Lens Type
|style="text-align:center;"|Permanent Magnet
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Permanent Magnet
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop IA]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens-Elmiskop-IA.jpg|200px|link=Elmiskop IA]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1961
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 101]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"| 200x to 200,000x
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|Galvanometer
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10⁻5Torr
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 60, 80, 100 KV
|-
! scope="row"|Stability
|style="text-align:center;"|2*10⁻⁵/min
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|X, Y, and Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|4 [https://en.wikipedia.org/wiki/Angstrom Å]
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|12.5:1, 31.2:1, 62.5:1, 125:1, 250:1?
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop 51]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Elmiskop51-overview-meek.jpg|200px|link=Elmiskop 51]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1956
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 51]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 50 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|0
|-
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry 9 position
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"| N/A
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|25-50 [https://en.wikipedia.org/wiki/Angstrom Å] Film Grain Dependent<ref>Geoffrey A. Meek, Practical Electron Microscopy for the Biologist, 2nd Edition (1976), Page 489</ref>
|-
! scope="row"|Lens Type
|style="text-align:center;"|Permanent Magnet
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|N/A
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Permanent Magnet
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop 101]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens Elmiskop-101-PLI.jpg|200px|link=Elmiskop 101]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1968
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 102]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 40, 60, 80, 100, 125 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|3-5 [https://en.wikipedia.org/wiki/Angstrom Å] <ref>Geoffrey A. Meek, Practical Electron Microscopy for the Biologist, 1st Edition (1970), Page 235</ref>
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|2 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}  
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop 102]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1972
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 103]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 40, 60, 80, 100, 125 KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|2 [https://en.wikipedia.org/wiki/Angstrom Å] (Line) 3 [https://en.wikipedia.org/wiki/Angstrom Å] (Point) <ref>Geoffrey A. Meek, Practical Electron Microscopy for the Biologist, 2nd Edition (1976), Page 502</ref>
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|1
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop 103]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"|
|-
! scope="row"|Successor
|style="text-align:center;"| [[Elmiskop 104]]
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]?
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]ß
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 40, 60, 80, 100, 125 KV ?
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|1
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop 104]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"|
|-
! scope="row"|Successor
|style="text-align:center;"| none
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]?
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]ß
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"| 40, 60, 80, 100, 125 KV ?
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|1
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|X, Y (via Rovolver Rotation) & Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop CT150]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1977
|-
! scope="row"|Successor
|style="text-align:center;"| none
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|
|-
! scope="row"| Cathode Type
|style="text-align:center;"|
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|}
|}
 
 
 
== Scanning Transmission Electron Microscops ==
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmiskop ST100F]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Elmiskop ST100F Overview - annotated.jpg|200px|link=Elmiskop ST100F]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1977
|-
! scope="row"|Successor
|style="text-align:center;"| none
|-
! scope="row"|Magnification Range
|style="text-align:center;"| 50x - 10e7X
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|10e-7 mBar
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|[[Crewe FE Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Cold Field Emmision]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|20, 40, 60, 80, 100 KV, (10 - 30 KV)
|-
! scope="row"|Stability
|style="text-align:center;"|2*10e-6
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|N/A
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|2*10e-6
|-
! scope="row"|Stigmator
|style="text-align:center;"|
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Crewe Electrostatic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|+- 1 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"| 1.8 mm
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|1.3 mm
|-
! scope="row"|Chromatic Error
|style="text-align:center;"|1.3 mm
|-
! scope="row"|Current Stability
|style="text-align:center;"| 1 * 10e-6
|-
! scope="row"|Stigmator
|style="text-align:center;"|Electromagnetic
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|2 [https://en.wikipedia.org/wiki/Angstrom Å]
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|
|}
|}
 
 
 
== X-Ray Micro Analyzers ==
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[Elmisonde]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Siemens - Elmisonde - Overview from Brochure.jpg|200px|link=Elmisonde]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1961
|-
! scope="row"|Successor
|style="text-align:center;"| none
|-
! scope="row"|Magnification Range
|style="text-align:center;"|
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"|
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"|
|-
! scope="row"|Power Consumption
|style="text-align:center;"|
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|40, 60, 80, 100 KV
|-
! scope="row"|Stability
|style="text-align:center;"|2*10⁻⁵/min
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|AC
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y, Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|2
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|X, Y, and Tilt, Mechanical
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|Cartridge, Top Entry
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"| ± 0.8 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|Moveing Iron, Mechanical
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Projective Lens
|-
! scope="row"|Number of Projective Lens
|style="text-align:center;"|1
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Polpeace Configuration
|style="text-align:center;"|4 Position Revolver
|-
! scope="row"|Avalible Polpeace Magnifications
|style="text-align:center;"|
|-
! scope="row"|Alignment
|style="text-align:center;"|
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}
== Scanning Electron Microscops ==
{| class="wikitable"
! scope="row" colspan="9" style="text-align:left;"|[[ETEC Autoscan| Autoscan]]
|-style="vertical-align:top;"
|style="text-align:center;vertical-align:middle;"|[[File:Autoscan Column.jpg|200px|link=ETEC Autoscan]]
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|General
|-
! scope="row"|Year
|style="text-align:center;"| 1972
|-
! scope="row"|Successor
|style="text-align:center;"| none
|-
! scope="row"|Magnification Range
|style="text-align:center;"| 20 - 550Kx
|-
! scope="row"|Magnification Gauge Type
|style="text-align:center;"| Analog, (Digital)
|-
! scope="row"|Specemin Chamber Pressure
|style="text-align:center;"| 2 * 10-4 Torr
|-
! scope="row"|Power Consumption
|style="text-align:center;"| 3 KVA
|-
! scope="row"|System Weight
|style="text-align:center;"|
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Electrion Source
|-
! scope="row"| Accelerator Type
|style="text-align:center;"|Single Stage [[Electron Gun]]
|-
! scope="row"| Cathode Type
|style="text-align:center;"|[[Tungsten Hairpin]] / [[LaB6]] / [[Field Emission?]]
|-
! scope="row"| Accelerating Voltage
|style="text-align:center;"|2.5, 5, 10, 20, 30, (50) KV
|-
! scope="row"|Stability
|style="text-align:center;"|
|-
! scope="row"|Cathode Heating Methode
|style="text-align:center;"|HF
|-
! scope="row"|Alignment Methode
|style="text-align:center;"|X, Y Mechanical
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Condensor
|-
! scope="row"|Number of Condensor Lenses
|style="text-align:center;"|3
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"|none
|-
! scope="row"|Minimum Spot Size Diameter
|style="text-align:center;"|
|-
! scope="row"|Condensor Alignment
|style="text-align:center;"|none, prealigned
|-
! scope="row"|Lens Type
|style="text-align:center;"|3 gap Common Coil Electromagnetic
|-
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Stage
|-
! scope="row"|Holder Type
|style="text-align:center;"|
|-
! scope="row"|X, Y Travel Range
|style="text-align:center;"|+- 12.5 mm
|-
! scope="row"|Z Travel Range
|style="text-align:center;"|25 mm
|}
|style="text-align:center;"|
{| class="wikitable"
! scope="row" colspan="2"|Objective Lens
|-
! scope="row"|Focal Length
|style="text-align:center;"|
|-
! scope="row"|Adjustment Range
|style="text-align:center;"|
|-
! scope="row"|Spherical Error
|style="text-align:center;"|
|-
! scope="row"|Current Stability
|style="text-align:center;"|
|-
! scope="row"|Stigmator
|style="text-align:center;"| Dual Quadropol Electromagnetic
|-
! scope="row"|Alignment Aids
|style="text-align:center;"|
|-
! scope="row"|Point Resolution
|style="text-align:center;"|7 nm
|-
! scope="row"|Lens Type
|style="text-align:center;"|Electromagnetic
|}
|}


*[[Elmiskop ST100F]]
**Service
***{"icon":false}{{#l:Siemens - C73389-A31-A1 A3- -98 - S1- Blatt 3- ST100F - Objektiv Sonderbauunterlage.tif|C73389-A31-A1 A3-*-98 - S1- Blatt 3- ST100F - Objektiv Sonderbauunterlage}}
**Promotional
***{"icon":false}{{#l:Siemens - E631-1014 - Elmiskop ST100F Brochure - German.pdf|E631/1014 - Elmiskop ST100F - Brochure}}


*[[Elmiskop CT150]]
**Promotional
***{"icon":false}{{#l:Siemens - E631-1016 - Elmiskop CT150 - Brochure.pdf|E631/1016 - Elmiskop CT150 - Brochure}}


= References =
*[[ETEC / Siemens Autoscan]]
<references />
= Documentation =
Full list of all documents related to the Siemens Electron Microscopes.
{{#tree:
*Elmiskop I & IA
**Manual
***{"icon":false}{{#l:Siemens - Elmiskop IA - Bedienungsanleitung - Band 2 - Bilder und Pläne.pdf|Bedienungsanleitung - Band 2 - Bilder und Pläne}}
**Promotional
**Promotional
***{"icon":false}{{#l:Siemens Elmiskop 1 - Brochure.pdf|Marketing Brochure}}
***{"icon":false}{{#l:ETEC - Seimens - E6331-1002 - Autoscan Brochure - German.pdf|E6331/1002 - Autoscan - Brochure}}
***{"icon":false}{{#l:Siemens Elmiskop 1 - Grossraum Objektkammer.pdf|Grossraum Objektkammer Brochure}}
***{"icon":false}{{#l:ETEC - Siemens - E633-1001-101 - Autoscan Brochure.pdf|E633/1001-101 - Autoscan - Brochure}}
***{"icon":false}{{#l:Siemens Elmiskop 1 - Objektheizeinrichtung.pdf|Objektheizeinrichtung Brochure}}
 
***{"icon":false}{{#l:Siemens Elmiskop 1 - Objektkühleinrichtung.pdf|Objektkühleinrichtung Brochure}}
***{"icon":false}{{#l:Siemens Elmiskop 1 - Objektraumkühlung.pdf|Objektraumkühlung Brochure}}
***{"icon":false}{{#l:Siemens Elmiskop 1 - Bildübertragungseinrichtung.pdf|Bildübertragungseinrichtung Brochure}}
***{"icon":false}{{#l:Siemens - Einrichtung für Außenkinematografie am Elmiskop 1A, 1 und Elmiskop II - comp.pdf|Einrichtung für Außenkinematografie Brochure}}
***{"icon":false}{{#l:Siemens - Einrichtung für Innenkinematographie zum Elmiskop 1, 1A und Elmisop II - comp.pdf|Einrichtung für Innenkinematographie Brochure}}
***{"icon":false}{{#l:Siemens - 70-mm.Filmkasette für das Elmiskop 1A, 1 und II - comp.pdf|70-mm.Filmkasette Brochure}}
***{"icon":false}{{#l:Siemens - Bildübertragungseinrichtung für Siemens-Elektronenmikroskope - comp.pdf|Bildübertragungseinrichtung Brochure}}
***{"icon":false}{{#l:Siemens - Einrichtung für Objektraumkühlung zum Elmiskop 1 und am Elmiskop 1A - comp.pdf|Einrichtung für Objektraumkühlung Brochure}}
***{"icon":false}{{#l:Siemens - Spitzenkathode zum Elmiskop IA und Elmiskop I - comp.pdf|Spitzenkathode Brochure}}
***{"icon":false}{{#l:Siemens - Objektkühleinrichtung zum Elmiskop 1A und Elmiskop 1 - comp.pdf|Objektkühleinrichtunge Brochure}}
***{"icon":false}{{#l:Siemens - Objektpatrone für Dehnungsverfahren zum Elmiskop IA und Elmiskop I - comp.pdf|Objektpatrone für Dehnungsverfahren Brochure}}
***{"icon":false}{{#l:Siemens - Elektrischer Belichtungsverschluß zum Elmiskop IA und Elmiskop II - comp.pdf|Elektrischer Belichtungsverschluß Brochure}}
***{"icon":false}{{#l:Siemens - Doppelkipp-Einrichtung für Objekte zum Elmiskop I und IA - comp.pdf|Doppelkipp-Einrichtung Brochure}}
***{"icon":false}{{#l:Siemens - Großraum-Objektkammer zum Elmiskop 1A und Elmiskop 1 - comp.pdf|Großraum-Objektkammer Brochure}}
***{"icon":false}{{#l:Siemens - Röntgenspektrometer-Zusatz zum Elmiskop IA und I - comp.pdf|Röntgenspektrometer-Zusatz Brochure}}
***{"icon":false}{{#l:Siemens - Objektheizeinrichtung zum Elmiskop IA und Elmiskop I - comp.pdf|Objektheizeinrichtung Brochure}}
***{"icon":false}{{#l:Siemens - Objektpatrone für Reflexionsbeugung zum Elmiskop IA, I und II - comp.pdf|Objektpatrone für Reflexionsbeugung Brochure}}
***{"icon":false}{{#l:Siemens - Einrichtung für Simultanbeugung zum Elmiskop I und IA - comp.pdf|Einrichtung für Simultanbeugung Brochure}}
***{"icon":false}{{#l:Siemens - Dünnwandige Objektivaperturblenden für die Elektronenmikroskopie - comp.pdf|Dünnwandige Objektivaperturblenden Brochure}}
***{"icon":false}{{#l:Siemens - Einrichtung für Röntgenmikroanalyse (RMA) zum Elmiskop Ia und Elmiskop I - comp.pdf|Einrichtung für Röntgenmikroanalyse (RMA) Brochure}}
*Price Lists / Catalogs
*Price Lists / Catalogs
**{"icon":false}{{#l:Siemens - Preisliste Eg1 - September 1971 - Elektronenmikroskope und Zubehör - compressed.pdf|September 1971 - Elektronenmikroskope und Zubehör - Preisliste Eg1}}
**{"icon":false}{{#l:Siemens - Preisliste Eg1 - September 1971 - Elektronenmikroskope und Zubehör - compressed.pdf|September 1971 - Elektronenmikroskope und Zubehör - Preisliste Eg1}}
**{"icon":false}{{#l:Siemens - Elektronenoptik aktuell.pdf|Elektronenoptik aktuell CT150 & ST100F}}
*EG Berichte
**{"icon":false}{{#l:Siemens - 1959- Elmiskop 1- Zusammenstellung der verwendeten Dichtungen - Bis Gerät 387.pdf
|1961 - Woche 40 - Elmiskop 1- Zusammenstellung der verwendeten Dichtungen - Bis Gerät 387}}
**{"icon":false}{{#l:Siemens - Elmiskop 1- Zusammenstellung der verwendeten Dichtungen - Ab Gerät 388.pdf
|1961 - Woche 41 - Elmiskop 1- Zusammenstellung der verwendeten Dichtungen - Ab Gerät 388}}
**{"icon":false}{{#l:Siemens - Eg1 - 1961 - 28 - Hinweise zur Präparation elektronenmikroskopischer Obiekte.pdf
|1961 - Woche 28 - Hinweise zur Präparation elektronenmikroskopischer Obiekte}}
**{"icon":false}{{#l:Siemens - Eg1 - 1961 - 32- Die Herstellung von Kohleaufdampfschichten.pdf
|1961 - Woche 32 - Die Herstellung von Kohleaufdampfschichten}}
**{"icon":false}{{#l:Siemens - Eg1 - nr11 - 1963 - w48 - Kurzanleitung zur Justierung des Elmiskop I.pdf
|1963 - Woche 48 - Kurzanleitung zur Justierung des Elmiskop I}}
**{"icon":false}{{#l:Siemens - Eg1 - nr14 - 1964 - Literatur und Bezugsquellen für Hilfsgeräte und -materialien zur Elektronenmikroskopie.pdf
|1964 - Woche 54 - Literatur und Bezugsquellen für Hilfsgeräte und -materialien zur Elektronenmikroskopie}}
*Fokus Infomration
**{"icon":false}{{#l:Siemens - Focus Information 1 - Hochleistungs Elektronenmikroskop Elmiskop 102.pdf
|Focus Information 1 - Hochleistungs Elektronenmikroskop Elmiskop 102}}
}}
}}


 
[[Category:Pages using DynamicPageList parser function]]


= Categorie Entries =
= Categorie Entries =

Latest revision as of 13:59, 1 December 2023

The Siemens Logo as seen in 1971

The Siemens Corperation has, throughout the years produced many things, among them was the very First Electron Microsocpe. The history of the Electron Microscope started with Siemenes and Ernst Ruska, together with his research team, they created the very first Electron Microscopes.

Timeline

<itimeline>

1939-01-01/1949-01-01|Universal|Übermikroskop 1949-01-01/1955-01-01|Universal|ÜM100 1954-01-01/1961-01-01|Universal|Elmiskop I 1961-01-01/1971-01-01|Universal|Elmiskop IA 1968-01-01/1971-01-01|Universal|Elmiskop 101 1971-01-01/1978-01-01|Universal|Elmiskop 102 1977-01-01/1978-01-01|Universal|Elmiskop CT150

1961-01-01/1971-01-01|EPMA|Elmisonde

1977-01-01/1978-01-01|STEM|Elmiskop ST100F

1949-01-01/1955-01-01|Budget|ÜM60 1955-01-01/1956-01-01|Budget|Elmiskop II 1956-01-01/1971-01-01|Budget|Elmiskop 51

1938-01-01|Experimental|Prototyp 1 1938-05-01|Experimental|Prototyp 2 1954-01-01|Experimental|Elmiskop II Prototype 1956-01-01|Experimental|Elmiskop 51 Prototype </itimeline>


Models

Siemens, as the company responsible for the invention of the Electron Microscope has produced many models throughout the years, also selling a rebadged version of the Etec Autoscan which was sold under the Siemens name outside the United States. Most of their models however where of the Transmission kind, mostly due to Ernst Ruskas Prescience.

Transmission Electron Microscops

{{#DeviceInfoBox2:tem|Prototyp 1|File:Siemens - Prototyp.png| OEM=File:Siemens & Halske - Logo - 1971.png; year=1938; successor=Prototyp 2; accel=Kanalstrahlrohr; accel_volt=75 KV; cath_type=Gas Discharge; conl_type=Electromagnetic; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery; |}}

{{#DeviceInfoBox2:tem|Prototyp 2|File:Ruska Prototype 3 - meek.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1938; successor=Übermikroskop; accel=Kanalstrahlrohr; accel_volt=75 KV; cath_type=Gas Discharge; conl_type=Electromagnetic; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery; objl_res=100a; |}}

{{#DeviceInfoBox2:tem|Übermikroskop|File:Siemens - Übermikroskop - Meek.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1939; successor=ÜM100; accel=Kanalstrahlrohr; accel_volt=75 KV; cath_type=Gas Discharge; conl_type=Electromagnetic; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery; objl_res=100a; |}}

{{#DeviceInfoBox2:tem|ÜM100|Siemens - ÜM100 - Ruska 1953.png| OEM=File:Siemens & Halske - Logo - 1971.png; year=1949; successor=Elmiskop I; accel=Self Biased Triode; accel_volt=40 KV, 60 KV, 80 KV, 100 KV; cath_type=Tungsten Hairpin; conl_type=Electromagnetic; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery; chamber=1·10⁻⁴ Torr; |}}

{{#DeviceInfoBox2:tem|ÜM60|| OEM=File:Siemens & Halske - Logo - 1971.png; year=1950; successor=Elmiskop II; accel=Self Biased Triode; accel_volt=40, 50, 60 KV; cath_type=Tungsten Hairpin; conl_type=Electromagnetic; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery;

|}}

{{#DeviceInfoBox2:tem|Elmiskop I|File:Elmiskop1-Front-Brochure.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1954; mag_range=200x - 200Kx; mag_gauge=Galvanometer; power=3.3 KVA; weight=1200 Kg; accel_stab=2·10⁻⁵⁄ₘᵢₙ; cath_heat=AC; successor=Elmiskop IA; accel=Self Biased Triode; accel_volt=40, 60, 80, 100 KV; cath_type=Tungsten Hairpin; conl_type=Electromagnetic; conl_no=2; conl_stab=1·10⁻³⁄ₘᵢₙ; conl_stig=Moveing Iron; conl_spot=2µm; xy=± 0.8 mm; objl_foc=2.8mm; objl_range=2.8mm to 7.4mm; objl_stab=1·10⁻⁵⁄ₘᵢₙ; objl_res=5Å; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=2; proj_stab=1·10⁻⁴⁄ₘᵢₙ; proj_conf=4 Polpiece Revolver; proj_mag=12.5:1, 31.2:1, 62.5:1, 125:1, 250:1; holder=Cartridge, Top Entery; chamber=1·10⁻⁴ Torr; objl_spher=3.3 mm; | {{#tree:

}} }}

{{#DeviceInfoBox2:tem|Elmiskop II Protoype|File:Siemens - Elmiskop II Prototype.png| OEM=File:Siemens & Halske - Logo - 1971.png; year=1954; successor=Elmiskop II; accel=Self Biased Steigerwald Triode; accel_volt=40, 50, 60 KV; cath_type=Tungsten Hairpin; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery; objl_stab=3·10⁻⁵⁄ₘᵢₙ; objl_res=25Å; proj_conf=4 Polpiece Revolver; |}}




{{#DeviceInfoBox2:tem|Elmiskop II|File:Siemens - Elmiskop II - Column 2.png| OEM=File:Siemens & Halske - Logo - 1971.png; year=1955; successor=Elmiskop 51; accel=Self Biased Steigerwald Triode; accel_volt=50 KV; accel_stab=5·10⁻⁵⁄ₘᵢₙ; cath_type=Tungsten Hairpin; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=1; holder=Cartridge, Top Entery; power=2 KVA; weight=700 Kg; objl_foc=1.8mm; objl_range=2.8mm to 7.4mm; objl_stab=3·10⁻⁵⁄ₘᵢₙ; objl_res=15Å; proj_conf=4 Polpiece Revolver; proj_mag=16.9:1, 69.9:1, 146:1, 300:1; conl_stig=Moveing Iron; mag_range=295x, 1925x, 8Kx, 17Kx, 35Kx; chamber=1·10⁻⁴Torr; |}}

{{#DeviceInfoBox2:tem|Elmiskop 51|File:Elmiskop51-overview-meek.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1956; accel=Self Biased Steigerwald Triode; accel_volt=50 KV; accel_stab=5·10⁻⁵⁄ₘᵢₙ; cath_type=Tungsten Hairpin; objl_type=Permanent Magnet; proj_type=Permanent Magnet; proj_no=1; objl_res=25-50Å; proj_conf=4 Polpiece Revolver; conl_stig=Moveing Iron; |}}

{{#DeviceInfoBox2:tem|Elmiskop IA|File:Siemens-Elmiskop-IA.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1961; mag_range=200x - 200Kx; mag_gauge=Galvanometer; power=3.3 KVA; weight=1200 Kg; accel_stab=2·10⁻⁵⁄ₘᵢₙ; cath_heat=AC; successor=Elmiskop 101; accel=Self Biased Triode; accel_volt=40, 60, 80, 100 KV; cath_type=Tungsten Hairpin; conl_type=Electromagnetic; conl_no=2; conl_stab=1·10⁻³⁄ₘᵢₙ; conl_stig=Moveing Iron; conl_spot=2µm; xy=± 0.8 mm; objl_foc=2.8mm; objl_range=2.8mm to 7.4mm; objl_stab=1·10⁻⁵⁄ₘᵢₙ; objl_res=5Å; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=2; proj_stab=1·10⁻⁴⁄ₘᵢₙ; proj_conf=4 Polpiece Revolver; proj_mag=12.5:1, 31.2:1, 62.5:1, 125:1, 250:1; holder=Cartridge, Top Entery; chamber=1·10⁻⁴Torr; objl_spher=3.3 mm; | }}

{{#DeviceInfoBox2:tem|Elmiskop 101|File:Siemens Elmiskop-101-PLI.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1968; mag_range=285x - 260Kx; mag_gauge=Galvanometer; successor=Elmiskop 102; accel=Self Biased Triode; accel_volt=40, 60, 80, 100, 125 KV; cath_type=Tungsten Hairpin; conl_type=Electromagnetic; conl_no=2; conl_stig=Electromagnetic Octopol; xy=± 0.8 mm; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=2; proj_conf=2 Polpiece Revolver; holder=Cartridge, Top Entery; |}}

{{#DeviceInfoBox2:tem|Elmiskop 102|Siemens-elmiskop102 from-brochure.png| OEM=File:Siemens & Halske - Logo - 1971.png; year=1972; mag_range=200x - 500Kx; mag_gauge=Digital; power=4 KVA; weight= Kg; accel_stab=2·10⁻⁶⁄ₘᵢₙ; cath_heat=DC; successor=Elmiskop 103; accel=Self Biased Triode; accel_volt=20, 40, 60, 80, 100, 125 KV; cath_type=Tungsten Hairpin, Tungsten Lancet; conl_type=Electromagnetic; conl_no=2; conl_stab=5·10⁻⁶⁄ₘᵢₙ; conl_stig=Electromagnetic Octopol; conl_spot=1.7µm / 0.5 µm; xy=± 1 mm; objl_foc=2.7mm; objl_range=1.6mm (20KV) to 7mm; objl_stab=< 2·10⁻⁶⁄ₘᵢₙ; objl_res=3Å; objl_type=Electromagnetic; proj_type=Electromagnetic; proj_no=3; proj_stab=<5·10⁻⁶⁄ₘᵢₙ; proj_conf=Single Polpiece; holder=Cartridge, Top Entery; chamber=5·10⁻⁶ Torr; objl_spher=2.9 mm; objl_chrom=2.1 mm; successor=Elmiskop CT150; | }} {{#DeviceInfoBox2:tem|Elmiskop CT150|Simens-Elmiskop-ct150-from-brochure.jpg| OEM=File:Siemens & Halske - Logo - 1971.png; year=1977; mag_gauge=Digital; mag_range=500x - 1200Kx; accel=Self Biased Triode; accel_volt=20, 40, 60, 80, 100, 125, 150 KV; accel_current=100nA → 100µA; power=5.5kVA; weight= 1800Kg; accel_stab=2·10⁻⁶⁄ₘᵢₙ; cath_heat=DC; cath_type=Tungsten Hairpin, Tungsten Lancet; conl_type=Electromagnetic; conl_no=2; conl_stab=<5·10⁻⁶⁄ₘᵢₙ; conl_stig=Electromagnetic Octopol; conl_spot=500 nm / 200 nm; holder=Side Entry; chamber=5·10⁻⁶ Torr; objl_spher=1.4 mm; objl_chrom=1.3 mm; objl_foc=1.7mm; objl_type=Electromagnetic; objl_stab=< 2·10⁻⁷⁄ₘᵢₙ; objl_res=3Å; proj_type=Electromagnetic; proj_no=3; proj_stab=<5·10⁻⁶⁄ₘᵢₙ; proj_conf=Single Polpiece; | }} {{#DeviceInfoBox2:tem|Elmiskop CT100|| OEM=File:Siemens & Halske - Logo - 1971.png; year=1977; mag_gauge=Digital; accel=Self Biased Triode; accel_volt=20, 40, 60, 80, 100 KV ?; | }}

~

Scanning Transmission Electron Microscops

Elmiskop ST100F
General
Year 1977
Successor none
Magnification Range 50x - 10e7X
Magnification Gauge Type
Specemin Chamber Pressure 10e-7 mBar
Power Consumption
System Weight
Electrion Source
Accelerator Type Crewe FE Electron Gun
Cathode Type Cold Field Emmision
Accelerating Voltage 20, 40, 60, 80, 100 KV, (10 - 30 KV)
Stability 2*10e-6
Cathode Heating Methode N/A
Alignment Methode
Condensor
Number of Condensor Lenses 1
Current Stability 2*10e-6
Stigmator
Minimum Spot Size Diameter
Condensor Alignment
Lens Type Crewe Electrostatic
Stage
Holder Type
X, Y Travel Range +- 1 mm
Objective Lens
Focal Length 1.8 mm
Adjustment Range
Spherical Error 1.3 mm
Chromatic Error 1.3 mm
Current Stability 1 * 10e-6
Stigmator Electromagnetic
Alignment Aids
Point Resolution 2 Å
Lens Type Electromagnetic
Projective Lens
Number of Projective Lens
Current Stability
Polpeace Configuration
Avalible Polpeace Magnifications
Alignment
Lens Type


X-Ray Micro Analyzers

Elmisonde
General
Year 1961
Successor none
Magnification Range
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type Single Stage Electron Gun
Cathode Type Tungsten Hairpin
Accelerating Voltage 40, 60, 80, 100 KV
Stability 2*10⁻⁵/min
Cathode Heating Methode AC
Alignment Methode X, Y, Mechanical
Condensor
Number of Condensor Lenses 2
Current Stability
Stigmator Moveing Iron, Mechanical
Minimum Spot Size Diameter
Condensor Alignment X, Y, and Tilt, Mechanical
Lens Type Electromagnetic
Stage
Holder Type Cartridge, Top Entry
X, Y Travel Range ± 0.8 mm
Objective Lens
Focal Length
Adjustment Range
Spherical Error
Current Stability
Stigmator Moveing Iron, Mechanical
Alignment Aids
Point Resolution
Lens Type Electromagnetic
Projective Lens
Number of Projective Lens 1
Current Stability
Polpeace Configuration 4 Position Revolver
Avalible Polpeace Magnifications
Alignment
Lens Type Electromagnetic

Scanning Electron Microscops

Autoscan
General
Year 1972
Successor none
Magnification Range 20 - 550Kx
Magnification Gauge Type Analog, (Digital)
Specemin Chamber Pressure 2 * 10-4 Torr
Power Consumption 3 KVA
System Weight
Electrion Source
Accelerator Type Single Stage Electron Gun
Cathode Type Tungsten Hairpin / LaB6 / Field Emission?
Accelerating Voltage 2.5, 5, 10, 20, 30, (50) KV
Stability
Cathode Heating Methode HF
Alignment Methode X, Y Mechanical
Condensor
Number of Condensor Lenses 3
Current Stability
Stigmator none
Minimum Spot Size Diameter
Condensor Alignment none, prealigned
Lens Type 3 gap Common Coil Electromagnetic
Stage
Holder Type
X, Y Travel Range +- 12.5 mm
Z Travel Range 25 mm
Objective Lens
Focal Length
Adjustment Range
Spherical Error
Current Stability
Stigmator Dual Quadropol Electromagnetic
Alignment Aids
Point Resolution 7 nm
Lens Type Electromagnetic


Documentation