Recreation of the ISI Logo
ISI also known as International Scientific Instruments was a Japanese Scanning Electron Microscope Manufacturer
List of Models
| Super-II
|
|
| General
|
| Year
|
1974
|
| Successor
|
[[]]
|
| Magnification Range
|
10x - 200kx
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
2, 5, 10, 15, 25kV
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
dual quadropole
|
| Deflection Type
|
double electromagnetic
|
| Point Resolution
|
7nm
|
| Lens Type
|
Electromagnetic
|
|
| Super-IIIA
|
|
| General
|
| Year
|
1974
|
| Successor
|
[[]]
|
| Magnification Range
|
10x - 200kx
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
2, 5, 10, 15, 25kV
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
dual quadropole
|
| Deflection Type
|
double electromagnetic
|
| Point Resolution
|
7nm
|
| Lens Type
|
Electromagnetic
|
|
| Model-7
|
|
| General
|
| Year
|
|
| Successor
|
[[]]
|
| Magnification Range
|
30x - 120kx
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
2, 15kV
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
dual quadropole
|
| Deflection Type
|
double electromagnetic
|
| Point Resolution
|
10nm
|
| Lens Type
|
Electromagnetic
|
|
| ISI-60
|
|
| General
|
| Year
|
|
| Successor
|
[[]]
|
| Magnification Range
|
10x - 200kx
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
2kv - 30kV
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
dual quadropole
|
| Deflection Type
|
double electromagnetic
|
| Point Resolution
|
6nm
|
| Lens Type
|
Electromagnetic
|
|
| System-100
|
|
| General
|
| Year
|
|
| Successor
|
[[]]
|
| Magnification Range
|
10x - 600kx
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
0kv - 40kV
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
dual quadropole
|
| Deflection Type
|
double electromagnetic
|
| Point Resolution
|
6nm
|
| Lens Type
|
Electromagnetic
|
|
| TV Mini-SEM
|
|
| General
|
| Year
|
1975
|
| Successor
|
[[]]
|
| Magnification Range
|
20x - 20kx
|
| Magnification Gauge Type
|
Step Switch markings
|
| Specemin Chamber Pressure
|
<5e-5 mBar (measured)
|
| Power Consumption
|
1 kVA
|
| System Weight
|
82 kg total (column 26 kg)
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
10kV
|
| Stability
|
|
| Cathode Heating Methode
|
DC
|
| Alignment Methode
|
XY Shift (Mechanical)
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
none
|
| Aperture
|
|
| Condensor Alignment
|
none
|
| Lens Type
|
Magnetic
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
Pull out Stage
|
| Sample Holder Type
|
15mm Cylinder
|
| X, Y Travel Range
|
+-7.5mm
|
| Z Travel Range
|
none
|
| Tilt Range
|
-30° to +60°
|
| Rotation Range
|
none
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
dual quadropole
|
| Deflection Type
|
double electromagnetic
|
| Point Resolution
|
<50nm
|
| Lens Type
|
Electromagnetic
|
|
List of Models
For a full list of Models created by ISI, view List of ISI Models, a version without images is available below.
The full list of Electron Microscope models created by ISI including overview Pictures (where available).
The full list of Electron Microscope models created by ISI including overview Pictures (where available).