Difference between revisions of "Trüb Täuber & Co"

From Electronen Mikroskopie Museum Nürnberg
Jump to navigation Jump to search
(Created page with "The company Trüb Täuber & Co is only known by user:lbochlter to have produced a single microsocpe model. = List of Models = {{Tem list entry|Microscope Name=Elektrostat...")
 
Line 2: Line 2:
  
 
= List of Models =
 
= List of Models =
{{Tem list entry|Microscope Name=Elektrostatic Übermikroskop|Microscope Picture File=Trüb Täuber & Co - Elektrostatisches Übermikroskop - 2.png|Year=c.a. 1949|Successor=Unkown|Magnification Range=12000x <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Kanalstrahlrohr|Cathode Type=Kanalstrahlrohr <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 80</ref>|Acceleration Voltage=30 - 50 KV <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Stability=|Cathode Heating Methode=N/A|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=20 - 50|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=1|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}}
+
{{Tem list entry|Microscope Name=Elektrostatic Übermikroskop|Microscope Picture File=Trüb Täuber & Co - Elektrostatisches Übermikroskop - 2.png|Year=c.a. 1949<ref>Die Übermikroskopie, Bodo von Berries, 1949</ref>|Successor=Unkown|Magnification Range=12000x <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Kanalstrahlrohr|Cathode Type=Kanalstrahlrohr <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 80</ref>|Acceleration Voltage=30 - 50 KV <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Stability=|Cathode Heating Methode=N/A|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=20 - 50|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=1|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}}
  
 
[[Category:Electron Microscope]]
 
[[Category:Electron Microscope]]

Revision as of 13:58, 7 October 2021

The company Trüb Täuber & Co is only known by user:lbochlter to have produced a single microsocpe model.

List of Models

Elektrostatic Übermikroskop
Trüb Täuber & Co - Elektrostatisches Übermikroskop - 2.png
General
Year c.a. 1949[1]
Successor Unkown
Magnification Range 12000x [2]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type Kanalstrahlrohr
Cathode Type Kanalstrahlrohr [3]
Accelerating Voltage 30 - 50 KV [4]
Stability
Cathode Heating Methode N/A
Alignment Methode
Condensor
Number of Condensor Lenses 1
Stability
Stigmator
Minimum Spot Size Diameter
Condensor Alignment
Lens Type
Stage
Holder Type
X, Y Travel Range
Objective Lens
Focal Length
Adjustment Range
Spherical Error
Stability
Stigmator
Alignment Aids
Point Resolution 20 - 50 Å
Lens Type Electrostatic
Projective Lens
Number of Projective Lens 1
Stability
Polpeace Configuration
Avalible Polpeace Magnification(s)
Alignment
Lens Type Electrostatic
  1. Die Übermikroskopie, Bodo von Berries, 1949
  2. Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79
  3. Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 80
  4. Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79