| Line 366: |
Line 366: |
| | |}} | | |}} |
| | | | |
| − | {{SEM List Entry
| |
| − | |Microscope Name=CamScan 3-30 ACV
| |
| − | |Microscope Picture File=Cambridge - CamScan 3-30 ACV - Overview.jpg
| |
| − | |Year=
| |
| − | |Successor=
| |
| − | |Magnification Range=
| |
| − | |Magnification Gauge Type=
| |
| − | |Specemin Chamber Pressure=
| |
| − | |Power Consumption=
| |
| − | |System Weight=
| |
| − | |Accelerator Type=Self Biased Triode Gun
| |
| − | |Cathode Type=Tungsten Hairpin
| |
| − | |Accelerating Voltage=
| |
| − | |Stability=
| |
| − | |Cathode Heating Methode=
| |
| − | |Alignment Methode=
| |
| − | |Number of Condensor Lenses=
| |
| − | |Condensor Current Stability=
| |
| − | |Condensor Stigmator=
| |
| − | |Condensor Aperture=
| |
| − | |Condensor Alignment=
| |
| − | |Condensor Lens Type=
| |
| − | |Stage Type=Non Eucentric
| |
| − | |Sample Holder Type=3.2 mm Stub
| |
| − | |X, Y Travel Range=
| |
| − | |Z Travel Range=
| |
| − | |Tilt Range=
| |
| − | |Rotation Range=
| |
| − | |Working Distance=
| |
| − | |Objective Spherical Error=
| |
| − | |Objective Current Stability=
| |
| − | |Objective Stigmator=Octopol
| |
| − | |Deflection Type=Double Deflection Electromagnetic
| |
| − | |Point Resolution=
| |
| − | |Lens Type=Electromagnetic
| |
| − | |Specimen Loading=
| |
| − | |Drive Mechanism=Micrometer Screw (Hand Operated)
| |
| − | }}
| |
| | | | |
| − | [[Category:EM Templates]]
| + | |
| | + | |
| | | | |
| | = Electron Probe Micro Analyzers = | | = Electron Probe Micro Analyzers = |
Latest revision as of 09:31, 16 August 2025
The Cambridge Instrument Company located in Cambridge UK, was the first commercial manufacturer of Scanning Electron Microscopes.
Scanning Electron Microscopes
| Cambridge SEM-1
|
|
| General
|
| Year
|
1953
|
| Successor
|
Stereoscan MKI
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
|
| Deflection Type
|
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan MKI
|
|
| General
|
| Year
|
1965
|
| Successor
|
Stereoscan MKII
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
|
| Deflection Type
|
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan MKII
|
|
| General
|
| Year
|
1966
|
| Successor
|
Stereoscan S4
|
| Magnification Range
|
20x - 100Kx
|
| Magnification Gauge Type
|
Needle & Range Switch
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
1247 Kg
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
Mechanical
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
None
|
| Aperture
|
|
| Condensor Alignment
|
None
|
| Lens Type
|
Electromagnetic, Polepiece & Capsule
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
25mm
|
| Z Travel Range
|
15mm
|
| Tilt Range
|
90°
|
| Rotation Range
|
360°
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
0 - 20mm
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan S4
|
| [[File:|200px|link=Stereoscan S4]]
|
| General
|
| Year
|
|
| Successor
|
Stereoscan S4-10
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan S4-10
|
|
| General
|
| Year
|
1972 - 1974
|
| Successor
|
Stereoscan S250 MK I
|
| Magnification Range
|
40x to 100Kx
|
| Magnification Gauge Type
|
Needle type & Range Switch
|
| Specemin Chamber Pressure
|
{{{Specemin Chamber Pressure}}}
|
| Power Consumption
|
4KW
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin / LaB6
|
| Accelerating Voltage
|
0 - 30 KV
|
| Stability
|
|
| Cathode Heating Methode
|
DC
|
| Alignment Methode
|
Mechanical & Magnetic
|
|
| Condensor
|
| Number of Condensor Lenses
|
2
|
| Current Stability
|
|
| Stigmator
|
none
|
| Aperture
|
|
| Condensor Alignment
|
none
|
| Lens Type
|
Electromagnetic, Polpiece and Capsule
|
|
| Stage
|
| Stage Type
|
Non Eucentric / Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
Stage Dependent 25mm
|
| Z Travel Range
|
Stage Dependent 15mm
|
| Tilt Range
|
Stage Dependent 90°
|
| Rotation Range
|
360°
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan model 180
|
|
| General
|
| Year
|
|
| Successor
|
[[]]
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan Model 600
|
|
| General
|
| Year
|
|
| Successor
|
[[]]
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan Model 100
|
|
| General
|
| Year
|
|
| Successor
|
[[]]
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| Stereoscan Model 250 MKII
|
|
| General
|
| Year
|
|
| Successor
|
Stereoscan Model 250 MKIII
|
| Magnification Range
|
|
| Magnification Gauge Type
|
|
| Specemin Chamber Pressure
|
|
| Power Consumption
|
|
| System Weight
|
|
|
| Electrion Source
|
| Accelerator Type
|
Self Biased Triode Gun
|
| Cathode Type
|
Tungsten Hairpin
|
| Accelerating Voltage
|
|
| Stability
|
|
| Cathode Heating Methode
|
|
| Alignment Methode
|
|
|
| Condensor
|
| Number of Condensor Lenses
|
|
| Current Stability
|
|
| Stigmator
|
|
| Aperture
|
|
| Condensor Alignment
|
|
| Lens Type
|
|
|
| Stage
|
| Stage Type
|
Non Eucentric
|
| Specimen Loading
|
|
| Sample Holder Type
|
3.2 mm Stub
|
| X, Y Travel Range
|
|
| Z Travel Range
|
|
| Tilt Range
|
|
| Rotation Range
|
|
| Drive Mechanism
|
Micrometer Screw (Hand Operated)
|
|
| Objective Lens
|
| Working Distance
|
|
| Spherical Error
|
|
| Current Stability
|
|
| Stigmator
|
Octopol
|
| Deflection Type
|
Double Deflection Electromagnetic
|
| Point Resolution
|
|
| Lens Type
|
Electromagnetic
|
|
| General |
| Mag. Range |
20x - 300Kx |
| Power Requirment |
2 KVA |
| System Weight |
628 Kg |
| Electron Source |
| Accelerator Type |
Self Biased Triode |
| Acellerating Voltage |
0.5 - 40 KV |
| Cathode |
Tungsten Hairpin / LaB6 |
| Column |
| Stigmator |
Electromagnetic Octopol |
| Claimed Resolution |
50Å |
Electron Probe Micro Analyzers