| = List of Models = | | = List of Models = |
− | {{Tem list entry|Microscope Name=Elektrostatic Übermikroskop|Microscope Picture File=Trüb Täuber & Co - Elektrostatisches Übermikroskop - 2.png|Year=c.a. 1949|Successor=Unkown|Magnification Range=12000x <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Kanalstrahlrohr|Cathode Type=Kanalstrahlrohr <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 80</ref>|Acceleration Voltage=30 - 50 KV <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Stability=|Cathode Heating Methode=N/A|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=20 - 50|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=1|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}} | + | {{Tem list entry|Microscope Name=Elektrostatic Übermikroskop|Microscope Picture File=Trüb Täuber & Co - Elektrostatisches Übermikroskop - 2.png|Year=c.a. 1949<ref>Die Übermikroskopie, Bodo von Berries, 1949</ref>|Successor=Unkown|Magnification Range=12000x <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Kanalstrahlrohr|Cathode Type=Kanalstrahlrohr <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 80</ref>|Acceleration Voltage=30 - 50 KV <ref>Elektronen Mikroskopie, H. Mahl & E. Gölz, 1951, page 79</ref>|Stability=|Cathode Heating Methode=N/A|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=20 - 50|Obj. Lens Type=Electrostatic|No. of Proj. Lenses=1|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electrostatic}} |
| | | |
| [[Category:Electron Microscope]] | | [[Category:Electron Microscope]] |
Latest revision as of 13:59, 7 October 2021
The company Trüb Täuber & Co is only known by user:lbochlter to have produced a single microsocpe model.
List of Models
Elektrostatic Übermikroskop
|
|
General
|
Year
|
c.a. 1949[1]
|
Successor
|
Unkown
|
Magnification Range
|
12000x [2]
|
Magnification Gauge Type
|
|
Specemin Chamber Pressure
|
|
Power Consumption
|
|
System Weight
|
|
|
Electrion Source
|
Accelerator Type
|
Kanalstrahlrohr
|
Cathode Type
|
Kanalstrahlrohr [3]
|
Accelerating Voltage
|
30 - 50 KV [4]
|
Stability
|
|
Cathode Heating Methode
|
N/A
|
Alignment Methode
|
|
|
Condensor
|
Number of Condensor Lenses
|
1
|
Stability
|
|
Stigmator
|
|
Minimum Spot Size Diameter
|
|
Condensor Alignment
|
|
Lens Type
|
Electromagnetic
|
|
Stage
|
Holder Type
|
|
X, Y Travel Range
|
|
|
Objective Lens
|
Focal Length
|
|
Adjustment Range
|
|
Spherical Error
|
|
Stability
|
|
Stigmator
|
|
Alignment Aids
|
|
Point Resolution
|
20 - 50 Å
|
Lens Type
|
Electrostatic
|
|
Projective Lens
|
Number of Projective Lens
|
1
|
Stability
|
|
Polpeace Configuration
|
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
|
Lens Type
|
Electrostatic
|
|
- ↑ Die Übermikroskopie, Bodo von Berries, 1949