Line 9: |
Line 9: |
| | | |
| {{Tem list entry|Microscope Name=HU-12A|Microscope Picture File=Hitachi-HU12A-Marburg.png|Year=1973|Successor=|Magnification Range=250x, 600 to 500Kx|Magnification Gauge Type=Digital|Specemin Chamber Pressure=|Power Consumption=3.5 KVA|System Weught=1480 Kg|Accelerator Type=|Cathode Type=|Acceleration Voltage=10 KV, 25 KV, 50 KV, 75 KV, 100 KV, 125 KV|Stability=|Cathode Heating Methode=DC|Alignment Methode=Automatic Mechanical|No. of Condensor Lenses=2|Condensor Stability=|Condensor Stigmator=Quadropol|Minimum Spot Size=|Condensor Alignment=Electromagnetic|Condensor Lens Type=|Holder Type=Top Entry & Side Entry|Travel Range=|Obj. Focal Length=2 mm|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=Quadropol|Obj. Alignment Aid=|Point Resolution=3|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=3|Proj. Stability=|Proj. Polpiece Config=Single Polpiece|Proj. Mag=|Proj. Alignment=Mechanical|Proj. Lens Type=}} | | {{Tem list entry|Microscope Name=HU-12A|Microscope Picture File=Hitachi-HU12A-Marburg.png|Year=1973|Successor=|Magnification Range=250x, 600 to 500Kx|Magnification Gauge Type=Digital|Specemin Chamber Pressure=|Power Consumption=3.5 KVA|System Weught=1480 Kg|Accelerator Type=|Cathode Type=|Acceleration Voltage=10 KV, 25 KV, 50 KV, 75 KV, 100 KV, 125 KV|Stability=|Cathode Heating Methode=DC|Alignment Methode=Automatic Mechanical|No. of Condensor Lenses=2|Condensor Stability=|Condensor Stigmator=Quadropol|Minimum Spot Size=|Condensor Alignment=Electromagnetic|Condensor Lens Type=|Holder Type=Top Entry & Side Entry|Travel Range=|Obj. Focal Length=2 mm|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=Quadropol|Obj. Alignment Aid=|Point Resolution=3|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=3|Proj. Stability=|Proj. Polpiece Config=Single Polpiece|Proj. Mag=|Proj. Alignment=Mechanical|Proj. Lens Type=}} |
| + | |
| + | {{Tem list entry|Microscope Name=H-300|Microscope Picture File=|Year=c.a. 1981|Successor=|Magnification Range=250x to 100Kx|Magnification Gauge Type=Digital|Specemin Chamber Pressure=10e-5 Torr|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=75 KV|Stability=5e-6/min|Cathode Heating Methode=DC|Alignment Methode=|No. of Condensor Lenses=2|Condensor Stability=2.5e-5/min|Condensor Stigmator=|Minimum Spot Size=5 µm|Condensor Alignment=Electromagnetic|Condensor Lens Type=|Holder Type=Side Entry|Travel Range=+-1 mm|Obj. Focal Length=2.6 mm|Obj. Adjustment Range=|Obj. Spherical Error=2.8 mm|Obj. Stability=10e-5/min|Obj. Stigmator=Quadropol|Obj. Alignment Aid=|Point Resolution=7|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=10e-5/min|Proj. Polpiece Config=Single Polpiece|Proj. Mag=|Proj. Alignment=Mecanical|Proj. Lens Type=Electromagnetic (P1), Permanent Magnet (P2)}} |
| + | |
| + | {{Tem list entry|Microscope Name=H-500|Microscope Picture File=|Year=C.a. 1981|Successor=|Magnification Range=100x to 800x|Magnification Gauge Type=Digital|Specemin Chamber Pressure=5e-6 Torr|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=10 KV, 25 KV, 75 KV, 100 KV, 125 KV|Stability=2e-6/min|Cathode Heating Methode=DC|Alignment Methode=|No. of Condensor Lenses=2|Condensor Stability=1e-6/min|Condensor Stigmator=Quadropol|Minimum Spot Size=500nm|Condensor Alignment=|Condensor Lens Type=|Holder Type=Top Entry & Side Entry|Travel Range=+-1 mm|Obj. Focal Length=1.9 mm|Obj. Adjustment Range=0.3 µm|Obj. Spherical Error=1.7 mm|Obj. Stability=1e-6/min|Obj. Stigmator=Quadropol|Obj. Alignment Aid=|Point Resolution=3 / 7|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=3|Proj. Stability=5e-6/min (P1), 1e-5 (P2, P3)|Proj. Polpiece Config=Single Polpiece|Proj. Mag=|Proj. Alignment=Mechanical|Proj. Lens Type=}} |
| + | |
| + | {{Tem list entry|Microscope Name=H-700|Microscope Picture File=|Year=C.a. 1981|Successor=|Magnification Range=200x to 300x|Magnification Gauge Type=Digital|Specemin Chamber Pressure=5e-6 Torr|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=75 KV, 100 KV, 150 KV, 175 KV, 200 KV|Stability=2e-6/min|Cathode Heating Methode=DC|Alignment Methode=|No. of Condensor Lenses=2|Condensor Stability=1e-6/min|Condensor Stigmator=Quadropol|Minimum Spot Size=500nm|Condensor Alignment=|Condensor Lens Type=|Holder Type=Top Entry & Side Entry|Travel Range=+-1 mm|Obj. Focal Length=3.8 mm|Obj. Adjustment Range=0.3 µm|Obj. Spherical Error=3.6 mm|Obj. Stability=1e-6/min|Obj. Stigmator=Quadropol|Obj. Alignment Aid=|Point Resolution=3 / 7|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=3|Proj. Stability=5e-6/min (P1), 1e-5 (P2, P3)|Proj. Polpiece Config=Single Polpiece|Proj. Mag=|Proj. Alignment=Mechanical|Proj. Lens Type=}} |
| | | |
| [[Category:Electron Microscope]] | | [[Category:Electron Microscope]] |
Revision as of 20:18, 14 December 2021
Hitachi is a multi sector Comapany based in Japan. Among its many products are Electron Microscopes, both of the Scanning and Transmission Veriaty. They are among the first company to Introduce and populerize the use of the Cold Field Emmision Electron source.
Transmition Electron Microscopes
HS-8
|
|
General
|
Year
|
|
Successor
|
HS-9
|
Magnification Range
|
1000x to 100Kx
|
Magnification Gauge Type
|
Galvanometer
|
Specemin Chamber Pressure
|
|
Power Consumption
|
2 KVA
|
System Weight
|
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
25 KV, 50 KV
|
Stability
|
|
Cathode Heating Methode
|
DC
|
Alignment Methode
|
Mechanical
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
|
Stigmator
|
|
Minimum Spot Size Diameter
|
|
Condensor Alignment
|
Tilt
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Top Entery
|
X, Y Travel Range
|
|
|
Objective Lens
|
Focal Length
|
3.5 mm
|
Adjustment Range
|
20%
|
Spherical Error
|
|
Stability
|
|
Stigmator
|
Mechanical Azimuth, Electrical Amplitude
|
Alignment Aids
|
|
Point Resolution
|
8 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
2
|
Stability
|
|
Polpeace Configuration
|
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Prealigned
|
Lens Type
|
Electromagnetic (P1), Permanent Magnet (P2)
|
|
HS-9
|
[[File:|200px|link=HS-9]]
|
General
|
Year
|
|
Successor
|
[[]]
|
Magnification Range
|
200x, 500x to 100Kx
|
Magnification Gauge Type
|
|
Specemin Chamber Pressure
|
|
Power Consumption
|
2 KVA
|
System Weight
|
500 Kg
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
50 KV, 75KV
|
Stability
|
|
Cathode Heating Methode
|
|
Alignment Methode
|
Mechanical
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
|
Stigmator
|
|
Minimum Spot Size Diameter
|
|
Condensor Alignment
|
Electromagnetic
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Top Entry
|
X, Y Travel Range
|
2mm
|
|
Objective Lens
|
Focal Length
|
2mm
|
Adjustment Range
|
|
Spherical Error
|
|
Stability
|
|
Stigmator
|
Octopol
|
Alignment Aids
|
|
Point Resolution
|
4.5 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
2
|
Stability
|
|
Polpeace Configuration
|
Single Polpiece
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Pre-Aligned
|
Lens Type
|
|
|
HU-11E
|
|
General
|
Year
|
|
Successor
|
HU-12A
|
Magnification Range
|
250x, 1000x to 300Kx (22 Steps)
|
Magnification Gauge Type
|
Direct Readout
|
Specemin Chamber Pressure
|
|
Power Consumption
|
3.5 KVA
|
System Weight
|
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
25 KV, 50 Kv, 75 KV, 100 KV
|
Stability
|
|
Cathode Heating Methode
|
DC
|
Alignment Methode
|
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
|
Stigmator
|
|
Minimum Spot Size Diameter
|
|
Condensor Alignment
|
Tilt, Mechanical
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Top Entry
|
X, Y Travel Range
|
|
|
Objective Lens
|
Focal Length
|
2.5mm, (5mm)
|
Adjustment Range
|
|
Spherical Error
|
|
Stability
|
|
Stigmator
|
Quadropol, Centerable
|
Alignment Aids
|
|
Point Resolution
|
3 to 5 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
2
|
Stability
|
|
Polpeace Configuration
|
2 Polpiece Turret
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Centerable, Mechanical
|
Lens Type
|
|
|
HU-12A
|
|
General
|
Year
|
1973
|
Successor
|
[[]]
|
Magnification Range
|
250x, 600 to 500Kx
|
Magnification Gauge Type
|
Digital
|
Specemin Chamber Pressure
|
|
Power Consumption
|
3.5 KVA
|
System Weight
|
1480 Kg
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
10 KV, 25 KV, 50 KV, 75 KV, 100 KV, 125 KV
|
Stability
|
|
Cathode Heating Methode
|
DC
|
Alignment Methode
|
Automatic Mechanical
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
|
Stigmator
|
Quadropol
|
Minimum Spot Size Diameter
|
|
Condensor Alignment
|
Electromagnetic
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Top Entry & Side Entry
|
X, Y Travel Range
|
|
|
Objective Lens
|
Focal Length
|
2 mm
|
Adjustment Range
|
|
Spherical Error
|
|
Stability
|
|
Stigmator
|
Quadropol
|
Alignment Aids
|
|
Point Resolution
|
3 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
3
|
Stability
|
|
Polpeace Configuration
|
Single Polpiece
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Mechanical
|
Lens Type
|
|
|
H-300
|
[[File:|200px|link=H-300]]
|
General
|
Year
|
c.a. 1981
|
Successor
|
[[]]
|
Magnification Range
|
250x to 100Kx
|
Magnification Gauge Type
|
Digital
|
Specemin Chamber Pressure
|
10e-5 Torr
|
Power Consumption
|
|
System Weight
|
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
75 KV
|
Stability
|
5e-6/min
|
Cathode Heating Methode
|
DC
|
Alignment Methode
|
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
2.5e-5/min
|
Stigmator
|
|
Minimum Spot Size Diameter
|
5 µm
|
Condensor Alignment
|
Electromagnetic
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Side Entry
|
X, Y Travel Range
|
+-1 mm
|
|
Objective Lens
|
Focal Length
|
2.6 mm
|
Adjustment Range
|
|
Spherical Error
|
2.8 mm
|
Stability
|
10e-5/min
|
Stigmator
|
Quadropol
|
Alignment Aids
|
|
Point Resolution
|
7 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
2
|
Stability
|
10e-5/min
|
Polpeace Configuration
|
Single Polpiece
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Mecanical
|
Lens Type
|
Electromagnetic (P1), Permanent Magnet (P2)
|
|
H-500
|
[[File:|200px|link=H-500]]
|
General
|
Year
|
C.a. 1981
|
Successor
|
[[]]
|
Magnification Range
|
100x to 800x
|
Magnification Gauge Type
|
Digital
|
Specemin Chamber Pressure
|
5e-6 Torr
|
Power Consumption
|
|
System Weight
|
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
10 KV, 25 KV, 75 KV, 100 KV, 125 KV
|
Stability
|
2e-6/min
|
Cathode Heating Methode
|
DC
|
Alignment Methode
|
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
1e-6/min
|
Stigmator
|
Quadropol
|
Minimum Spot Size Diameter
|
500nm
|
Condensor Alignment
|
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Top Entry & Side Entry
|
X, Y Travel Range
|
+-1 mm
|
|
Objective Lens
|
Focal Length
|
1.9 mm
|
Adjustment Range
|
0.3 µm
|
Spherical Error
|
1.7 mm
|
Stability
|
1e-6/min
|
Stigmator
|
Quadropol
|
Alignment Aids
|
|
Point Resolution
|
3 / 7 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
3
|
Stability
|
5e-6/min (P1), 1e-5 (P2, P3)
|
Polpeace Configuration
|
Single Polpiece
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Mechanical
|
Lens Type
|
|
|
H-700
|
[[File:|200px|link=H-700]]
|
General
|
Year
|
C.a. 1981
|
Successor
|
[[]]
|
Magnification Range
|
200x to 300x
|
Magnification Gauge Type
|
Digital
|
Specemin Chamber Pressure
|
5e-6 Torr
|
Power Consumption
|
|
System Weight
|
|
|
Electrion Source
|
Accelerator Type
|
|
Cathode Type
|
|
Accelerating Voltage
|
75 KV, 100 KV, 150 KV, 175 KV, 200 KV
|
Stability
|
2e-6/min
|
Cathode Heating Methode
|
DC
|
Alignment Methode
|
|
|
Condensor
|
Number of Condensor Lenses
|
2
|
Stability
|
1e-6/min
|
Stigmator
|
Quadropol
|
Minimum Spot Size Diameter
|
500nm
|
Condensor Alignment
|
|
Lens Type
|
|
|
Stage
|
Holder Type
|
Top Entry & Side Entry
|
X, Y Travel Range
|
+-1 mm
|
|
Objective Lens
|
Focal Length
|
3.8 mm
|
Adjustment Range
|
0.3 µm
|
Spherical Error
|
3.6 mm
|
Stability
|
1e-6/min
|
Stigmator
|
Quadropol
|
Alignment Aids
|
|
Point Resolution
|
3 / 7 Å
|
Lens Type
|
Electromagnetic
|
|
Projective Lens
|
Number of Projective Lens
|
3
|
Stability
|
5e-6/min (P1), 1e-5 (P2, P3)
|
Polpeace Configuration
|
Single Polpiece
|
Avalible Polpeace Magnification(s)
|
|
Alignment
|
Mechanical
|
Lens Type
|
|
|