(One intermediate revision by the same user not shown) Line 510:
Line 510:
|Drive Mechanism=Micrometer Screw (Hand Operated)
|Drive Mechanism=Micrometer Screw (Hand Operated)
}}
}}
{{SEM List Entry
|Microscope Name=ISI-60A
|Microscope Picture File=ISI - ISI-60A - from N26D0045.png
|Year=
|Successor=
|Magnification Range=10x - 600kx<ref name="ISI-100B"/>
|Magnification Gauge Type= LED 7 segment Digital
|Specemin Chamber Pressure=
|Power Consumption=
|System Weight=
|Accelerator Type=Self Biased Triode Gun
|Cathode Type=Tungsten Hairpin
|Accelerating Voltage= 1kv - 30kV<ref name="ISI-100B"/>
|Stability=
|Cathode Heating Methode=
|Alignment Methode=
|Number of Condensor Lenses=2
|Condensor Current Stability=
|Condensor Stigmator=
|Condensor Aperture=
|Condensor Alignment=
|Condensor Lens Type=
|Stage Type=Non Eucentric
|Sample Holder Type=
|X, Y Travel Range=
|Z Travel Range=
|Tilt Range=
|Rotation Range=
|Working Distance=
|Objective Spherical Error=
|Objective Current Stability=
|Objective Stigmator= dual quadropole
|Deflection Type= double electromagnetic
|Point Resolution= 6nm (guaranteed), 5nm (attainable)<ref name="ISI-100B"/>
|Lens Type=Electromagnetic
|Specimen Loading=
|Drive Mechanism=Micrometer Screw (Hand Operated)
}}
{{SEM List Entry
|Microscope Name=ISI-100B
|Microscope Picture File=ISI_-_ISI-100B_-_from_N26D0045.png
|Year=
|Successor=
|Magnification Range=10x - 600kx<ref name="ISI-100B">[[:|ISI-60A and ISI-100B, Research scanning electron microscopes]]</ref>
|Magnification Gauge Type= LED 7 segment Digital
|Specemin Chamber Pressure=
|Power Consumption=
|System Weight=
|Accelerator Type=Self Biased Triode Gun
|Cathode Type=Tungsten Hairpin
|Accelerating Voltage= 1kv - 40kV<ref name="ISI-100B"/>
|Stability=
|Cathode Heating Methode=
|Alignment Methode=
|Number of Condensor Lenses=2
|Condensor Current Stability=
|Condensor Stigmator=
|Condensor Aperture=
|Condensor Alignment=
|Condensor Lens Type=
|Stage Type=Non Eucentric
|Sample Holder Type=
|X, Y Travel Range=
|Z Travel Range=
|Tilt Range=
|Rotation Range=
|Working Distance=
|Objective Spherical Error=
|Objective Current Stability=
|Objective Stigmator= dual quadropole
|Deflection Type= double electromagnetic
|Point Resolution= 6nm (guaranteed), 5nm (attainable)<ref name="ISI-100B"/>
|Lens Type=Electromagnetic
|Specimen Loading=
|Drive Mechanism=Micrometer Screw (Hand Operated)
}}
{{SEM List Entry
{{SEM List Entry
Line 695:
Line 775:
|}
|}
[[Category:EM Templates]]
[[Category:Electron Microscope]]
[[Category:Pages with reference errors]]
= References =
= References =
Recreation of the ISI Logo
ISI (international Scientific Instruments) was founded in 1972 and was a reseller of Scanning Electron Microscopes from the united states, who resold machines built by Akashi-Seisakusho, Ltd of Tokyo Japan. Their headquarters was located in Santa Clara California, United States of Amerika.
The involvement of ISI in the design of machines by Akashi is unknown to the museum at time of writing. It is likely they influenced the designs Akashi created.
List of Models
MSM-2
General
Year
Successor
[[]]
Magnification Range
30x - 40kx[ 1]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
1 kVA[ 1]
System Weight
90 kg total, (Column 26 kg)[ 1]
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
15kV [ 1]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2[ 1]
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
45° Fixed
Rotation Range
Drive Mechanism
unkown
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
30nm [ 1]
Lens Type
Electromagnetic
Super-I
General
Year
1974[ 2]
Successor
Super Mini-SEM I
Magnification Range
30x - 160kx[ 3]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
2, 15, 25kV[ 3]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
7nm (10nm Guaranteed) [ 3]
Lens Type
Electromagnetic
Super Mini-SEM I
[[File:|200px|link=Super Mini-SEM I]]
General
Year
Successor
[[]]
Magnification Range
30x - 160kx[ 4]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
2, 10, 25kV, 2, 15, 25kV, 10, 15, 25kV[ 4]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
10nm[ 4]
Lens Type
Electromagnetic
Super-II
General
Year
Successor
Super Mini-SEM II
Magnification Range
10x - 200kx[ 2] / 10x - 160kx[ 3]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
2, 5, 10, 15, 25kV[ 2] [ 3]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
7nm[ 2]
Lens Type
Electromagnetic
Super Mini-SEM II
General
Year
Successor
[[]]
Magnification Range
30x - 160kx[ 4]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
10, 15, 25kV, 2, 10, 25kV, 2, 15, 25kV, [ 4]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
7nm [ 4]
Lens Type
Electromagnetic
Super-III / SMSM-III
General
Year
Successor
[[]]
Magnification Range
10x - 160kx[ 3] [ 5]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin / LaB₆[ 5]
Accelerating Voltage
2, 5, 10, 15, 25kV[ 3] [ 5]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
7 nm[ 5] / 6 nm (LaB₆) [ 3] [ 5]
Lens Type
Electromagnetic
Super-IIIA
General
Year
Successor
[[]]
Magnification Range
10x - 200kx[ 2]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
2, 5, 10, 15, 25kV[ 2]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
7nm[ 2]
Lens Type
Electromagnetic
Model-7
General
Year
Successor
[[]]
Magnification Range
30x - 120kx[ 2]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
2, 15kV[ 2]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
10nm[ 2]
Lens Type
Electromagnetic
MRS "Mini-Rapid Scan"
[[File:|200px|link=MRS "Mini-Rapid Scan"]]
General
Year
Successor
TV Mini-SEM
Magnification Range
50x - 12kx [ 6]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
1 kVA[ 6]
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
8kV[ 6]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Magnetic
Stage
Stage Type
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
0 to 60°[ 6]
Rotation Range
none
Drive Mechanism
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
Deflection Type
Point Resolution
<75nm[ 6]
Lens Type
Electromagnetic
Mini-SEM
General
Year
Successor
[[]]
Magnification Range
30x - 80kx[ 3]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
15 kV[ 3]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
20nm [ 3]
Lens Type
Electromagnetic
TV Mini-SEM
General
Year
1975
Successor
[[]]
Magnification Range
20x - 20kx[ 3]
Magnification Gauge Type
Step Switch markings
Specemin Chamber Pressure
<5e-5 mBar (measured)
Power Consumption
1 kVA
System Weight
82 kg total (column 26 kg)
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
10kV[ 3]
Stability
Cathode Heating Methode
DC
Alignment Methode
XY Shift (Mechanical)
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
none
Aperture
Condensor Alignment
none
Lens Type
Magnetic
Stage
Stage Type
Non Eucentric
Specimen Loading
Pull out Stage
Sample Holder Type
15mm Cylinder
X, Y Travel Range
+-7.5mm
Z Travel Range
none
Tilt Range
-30° to +60°
Rotation Range
none
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
<50nm[ 3]
Lens Type
Electromagnetic
ISI-60
General
Year
Successor
[[]]
Magnification Range
10x - 200kx[ 2]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
2kv - 30kV[ 2]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
6nm[ 2]
Lens Type
Electromagnetic
System-100
General
Year
Successor
[[]]
Magnification Range
10x - 600kx[ 2]
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
0kv - 40kV[ 2]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
6nm[ 2]
Lens Type
Electromagnetic
ISI-60A
General
Year
Successor
[[]]
Magnification Range
10x - 600kx[ 7]
Magnification Gauge Type
LED 7 segment Digital
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
1kv - 30kV[ 7]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
6nm (guaranteed), 5nm (attainable)[ 7]
Lens Type
Electromagnetic
ISI-100B
General
Year
Successor
[[]]
Magnification Range
10x - 600kx[ 7]
Magnification Gauge Type
LED 7 segment Digital
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Self Biased Triode Gun
Cathode Type
Tungsten Hairpin
Accelerating Voltage
1kv - 40kV[ 7]
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
2
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Non Eucentric
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Micrometer Screw (Hand Operated)
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
6nm (guaranteed), 5nm (attainable)[ 7]
Lens Type
Electromagnetic
DS 130F
General
Year
1989
Successor
[[]]
Magnification Range
Magnification Gauge Type
Specemin Chamber Pressure
Power Consumption
System Weight
Electrion Source
Accelerator Type
Cathode Type
Field Emission (unkown type)
Accelerating Voltage
Stability
Cathode Heating Methode
Alignment Methode
Condensor
Number of Condensor Lenses
Current Stability
Stigmator
Aperture
Condensor Alignment
Lens Type
Stage
Stage Type
Specimen Loading
Sample Holder Type
X, Y Travel Range
Z Travel Range
Tilt Range
Rotation Range
Drive Mechanism
Hand Operated
Objective Lens
Working Distance
Spherical Error
Current Stability
Stigmator
dual quadropole
Deflection Type
double electromagnetic
Point Resolution
Lens Type
Electromagnetic
List of Models
Note: This list is deprecated and will be eventually removed once all entries can be updated with manufacturer pictures and information, as it becomes available to the museum.
For a full list of Models created by ISI, view List of ISI Models , a version without images is available below.
The full list of Electron Microscope models created by ISI including overview Pictures (where available).
The full list of Electron Microscope models created by ISI including overview Pictures (where available).
References