Difference between revisions of "Cambridge"
(fixed the name of the 440) |
|||
| (35 intermediate revisions by the same user not shown) | |||
| Line 2: | Line 2: | ||
= Scanning Electron Microscopes = | = Scanning Electron Microscopes = | ||
| − | |||
| − | {{SEM List Entry|Microscope Name= | + | {{SEM List Entry |
| + | |Microscope Name=Cambridge SEM-1 | ||
| + | |Microscope Picture File=Cambridge-SEM1-taken-in-1953-38-p52.png | ||
| + | |Year=1953 | ||
| + | |Successor=Stereoscan MKI | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type= | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator= | ||
| + | |Deflection Type= | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| − | {{SEM List Entry|Microscope Name=Stereoscan | + | {{SEM List Entry |
| + | |Microscope Name=Stereoscan MKI | ||
| + | |Microscope Picture File=Cambridge Stereoscan MK1 2.png | ||
| + | |Year=1965 | ||
| + | |Successor=Stereoscan MKII | ||
| + | |Magnification Range= 20x - 100Kx | ||
| + | |Magnification Gauge Type= Needle & Range Switch | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= 4.5 - 5kVA | ||
| + | |System Weight= 2064 kg | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= 1 kV - 20 kV | ||
| + | |Stability= 30 ppm / 5 min | ||
| + | |Cathode Heating Methode= DC | ||
| + | |Alignment Methode= Mechanical XYZ | ||
| + | |Number of Condensor Lenses= 2 | ||
| + | |Condensor Current Stability= 15 ppm / 5 min | ||
| + | |Condensor Stigmator= None | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= None | ||
| + | |Condensor Lens Type= Electromagnetic, Polepiece & Capsule | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= 25mm | ||
| + | |Z Travel Range= 15mm | ||
| + | |Tilt Range= 90° | ||
| + | |Rotation Range= 360° | ||
| + | |Working Distance= 0 - 20mm | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= 15 ppm / 5 min | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <20 nm | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| − | {{SEM List Entry|Microscope Name=Stereoscan | + | {{SEM List Entry |
| + | |Microscope Name=Stereoscan MKII | ||
| + | |Microscope Picture File=Cambridge-Stereoscan-mk2-redrawn.jpg | ||
| + | |Year= 1966 | ||
| + | |Successor=Stereoscan S4 | ||
| + | |Magnification Range= 20x - 100Kx | ||
| + | |Magnification Gauge Type= Needle & Range Switch | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= 4.5 - 5kVA | ||
| + | |System Weight= 1247 Kg (2064kg) | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= 1 kV - 20 kV | ||
| + | |Stability= 30 ppm / 5 min | ||
| + | |Cathode Heating Methode= DC | ||
| + | |Alignment Methode= Mechanical XYZ | ||
| + | |Number of Condensor Lenses= 2 | ||
| + | |Condensor Current Stability= 15 ppm / 5 min | ||
| + | |Condensor Stigmator= None | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= None | ||
| + | |Condensor Lens Type= Electromagnetic, Polepiece & Capsule | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= 25mm | ||
| + | |Z Travel Range= 15mm | ||
| + | |Tilt Range= 90° | ||
| + | |Rotation Range= 360° | ||
| + | |Working Distance= 0 - 20mm | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= 15 ppm / 5 min | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <15 nm | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| − | {{SEM List Entry|Microscope Name= | + | {{SEM List Entry |
| + | |Microscope Name=Stereoscan S4 | ||
| + | |Microscope Picture File=Cambridge Stereoscan S4 from brochure.png | ||
| + | |Year= 1969 | ||
| + | |Successor=Stereoscan S4-10 | ||
| + | |Magnification Range= 40x to 100Kx | ||
| + | |Magnification Gauge Type= Needle type & Range Switch | ||
| + | |Specemin Chamber Pressure= < 5 e-5 mBar | ||
| + | |Power Consumption= 4.5 kVA | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= 0 - 30 KV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= DC | ||
| + | |Alignment Methode= Mechanical XYZ | ||
| + | |Number of Condensor Lenses= 2 | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= Electromagnetic, Polepiece & Capsule | ||
| + | |Stage Type=Non Eucentric & Eucentric (optional) | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= +-12.5 mm | ||
| + | |Z Travel Range= 35mm | ||
| + | |Tilt Range= 45° | ||
| + | |Rotation Range= 360° | ||
| + | |Working Distance= 0 - 20mm | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <15 nm | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan S4-10 | ||
| + | |Microscope Picture File=Cambridge_s4-10_from_manual.png | ||
| + | |Year=1972 - 1974 | ||
| + | |Successor=Stereoscan S250 MK I | ||
| + | |Magnification Range=40x to 100Kx | ||
| + | |Magnification Gauge Type= Needle type & Range Switch | ||
| + | |Specemen Chamber Pressure= < 5 e-5 mBar | ||
| + | |Power Consumption= 4 kVA | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin / LaB6 | ||
| + | |Accelerating Voltage= 0 - 30 KV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= DC | ||
| + | |Alignment Methode= Mechanical & Magnetic | ||
| + | |Number of Condensor Lenses= 2 | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= none | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= none | ||
| + | |Condensor Lens Type= Electromagnetic, Polpiece and Capsule | ||
| + | |Stage Type=Non Eucentric / Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= Stage Dependent 25mm | ||
| + | |Z Travel Range=Stage Dependent 15mm | ||
| + | |Tilt Range= Stage Dependent 90° | ||
| + | |Rotation Range= 360° | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 180 | ||
| + | |Microscope Picture File=Cambridge_Stereoscan_180_from_program_overview.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 150 | ||
| + | |Microscope Picture File=Cambridge_Stereoscan_150_from_program_overview.png | ||
| + | |Year= | ||
| + | |Successor= Stereoscan 150 Mk 2 | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 600 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 600 from brochure.png | ||
| + | |Year= 1976 | ||
| + | |Successor= | ||
| + | |Magnification Range= 20x to 50kx | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption=2.6 kVA | ||
| + | |System Weight= 454 kg (base configuration) | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage=1.5, 7.5, 15, 25 kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= 13 mm | ||
| + | |Z Travel Range= 20 mm | ||
| + | |Tilt Range= 0-90° | ||
| + | |Rotation Range= 360° | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <25 nm | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Palette Stage | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 150 Mk 2 | ||
| + | |Microscope Picture File= Cambridge_Stereoscan_150_Mk2_from_brochure.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin / LaB6 | ||
| + | |Accelerating Voltage= 1 - 40 kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= +- 50mm | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= 6 nm | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 250 Mk 1 | ||
| + | |Microscope Picture File= Cambridge - Stereoscan 250 MK2 - overview.jpg | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 250 MKII | ||
| + | |Microscope Picture File= | ||
| + | |Year= | ||
| + | |Successor=Stereoscan Model 250 MKIII | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 250 MKIII | ||
| + | |Microscope Picture File=Cambridge Stereoscan 250 MK III from brochure.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= 20x - 300kx | ||
| + | |Magnification Gauge Type= Digital | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= 2 kVA | ||
| + | |System Weight= 628 Kg | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= 500v - 40kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= DC | ||
| + | |Alignment Methode= Electromagnetic | ||
| + | |Number of Condensor Lenses= 2 | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= 100mm - 3.5mm | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <5 nm (Tungsten) / <3.5 nm (LaB6) | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swingout Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor r | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 90 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 90 from brochure.png | ||
| + | |Year= | ||
| + | |Successor=Stereoscan 120 | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 100 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 100 from 250 MK3 brochure.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | |||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 200 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 200 from 250 MK3 brochure.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin / LaB6 | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Micrometer Screw (Hand Operated) | ||
| + | }} | ||
| + | |||
| + | |||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 120 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 120 from infosheet.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= 0.3 kV - 30 kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <5 nm | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 240 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 240 from infosheet.png | ||
| + | |Year= 1986 | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin / LaB6 | ||
| + | |Accelerating Voltage= 0.3 kV - 30 kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= DC | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= <4.5 nm (Tungsten) / <3.5 nm (LaB6) | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 260 | ||
| + | |Microscope Picture File=Cambridge_Stereoscan_260_from_360_brochure.png | ||
| + | |Year=1990 | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin | ||
| + | |Accelerating Voltage= | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 360 | ||
| + | |Microscope Picture File=Cambridge Stereoscan 360 from infosheet.png | ||
| + | |Year=1990 | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type=Tungsten Hairpin / LaB6 | ||
| + | |Accelerating Voltage= 200 v - 40 kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses=2 | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= Electromagnetc | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= 3.5 nm (Tungsten) / 2.5 nm (LaB6) | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 360FE | ||
| + | |Microscope Picture File=Cambridge_Stereoscan_360FE_from_cambridge_range_brochure.png | ||
| + | |Year=1991 | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type= | ||
| + | |Cathode Type= Field Emission (unknown type) | ||
| + | |Accelerating Voltage= 500V - 25kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= 2 nm (25kV) | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | |||
| + | |||
| + | == Leica Cambridge == | ||
| + | Cambridge Instruments was purchased by Leica c.a. 1990, where the company was then called Leica Cambridge, before Leica and Zeiss created the LEO cooperation, which inevitably lead the Cambridge electron microscope division merging into Zeiss. | ||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 420 | ||
| + | |Microscope Picture File=Leica_Stereoscan_420_from_cambridge_range_brochure.png | ||
| + | |Year=1991 | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type= Tungsten Hairpin | ||
| + | |Accelerating Voltage= 300V - 30kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= 5 nm (30kV) | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan 440 | ||
| + | |Microscope Picture File=Leica_Stereoscan_440_from_cambridge_range_brochure.png | ||
| + | |Year=1991 | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type= Tungsten Hairpin | ||
| + | |Accelerating Voltage= 300V - 30kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= | ||
| + | |Alignment Methode= | ||
| + | |Number of Condensor Lenses= | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type=Non Eucentric | ||
| + | |Sample Holder Type=3.2 mm Stub | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= 4.5 nm (30kV) | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Swing out Door | ||
| + | |Drive Mechanism=Crank (Hand Operated) / Motor | ||
| + | }} | ||
| + | |||
| + | [[Category:EM Templates]] | ||
| + | |||
| + | = Electron Probe Micro Analyzers = | ||
| + | *Microscan V | ||
| + | *[[Cambridge Geoscan|Geoscan]] | ||
| + | |||
| + | = Electron Beam Lithography Machines = | ||
| + | Cambridge built a few Electron Beam Lithography machines based on the Stereoscan S4-10, not much more is currently known about them by the museum, more information is needed. The first currently known system at the moment, is the Stereoscan Electron Beam Microfabrication System, wich was capable of making masks down to 100nm line width, and operated from what appears to be a PDP 11/20 mini computer. | ||
| + | {{SEM List Entry | ||
| + | |Microscope Name=Stereoscan EBMF (Electron Beam Microfabrication System) | ||
| + | |Microscope Picture File=Cambridge_EBMF_System.png | ||
| + | |Year= | ||
| + | |Successor= | ||
| + | |Magnification Range= | ||
| + | |Magnification Gauge Type= Dial & Galvanometer | ||
| + | |Specemin Chamber Pressure= | ||
| + | |Power Consumption= | ||
| + | |System Weight= | ||
| + | |Accelerator Type=Self Biased Triode Gun | ||
| + | |Cathode Type= LaB6 / Tungsten Hairpin | ||
| + | |Accelerating Voltage=0-30 kV | ||
| + | |Stability= | ||
| + | |Cathode Heating Methode= Electron Beam Bombardment / DC | ||
| + | |Alignment Methode= XY Shift, Z height (Mechanical) | ||
| + | |Number of Condensor Lenses= 2 | ||
| + | |Condensor Current Stability= | ||
| + | |Condensor Stigmator= | ||
| + | |Condensor Aperture= | ||
| + | |Condensor Alignment= | ||
| + | |Condensor Lens Type= | ||
| + | |Stage Type= | ||
| + | |Sample Holder Type= | ||
| + | |X, Y Travel Range= | ||
| + | |Z Travel Range= | ||
| + | |Tilt Range= | ||
| + | |Rotation Range= | ||
| + | |Working Distance= | ||
| + | |Objective Spherical Error= | ||
| + | |Objective Current Stability= | ||
| + | |Objective Stigmator=Octopol | ||
| + | |Deflection Type=Double Deflection Electromagnetic | ||
| + | |Point Resolution= | ||
| + | |Lens Type=Electromagnetic | ||
| + | |Specimen Loading= Stage Drawer | ||
| + | |Drive Mechanism= | ||
| + | }} | ||
[[Category:EM Templates]] | [[Category:EM Templates]] | ||
Latest revision as of 22:52, 30 June 2026
The Cambridge Instrument Company located in Cambridge UK, was the first commercial manufacturer of Scanning Electron Microscopes.
Scanning Electron Microscopes
| Cambridge SEM-1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan MKI | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan MKII | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan S4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan S4-10 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 180 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 150 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 600 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 150 Mk 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 250 Mk 1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 250 MKII | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| [[File:|200px|link=Stereoscan 250 MKII]] |
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 250 MKIII | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 90 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 100 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 200 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 120 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 240 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 260 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 360 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 360FE | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Leica Cambridge
Cambridge Instruments was purchased by Leica c.a. 1990, where the company was then called Leica Cambridge, before Leica and Zeiss created the LEO cooperation, which inevitably lead the Cambridge electron microscope division merging into Zeiss.
| Stereoscan 420 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stereoscan 440 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electron Probe Micro Analyzers
- Microscan V
- Geoscan
Electron Beam Lithography Machines
Cambridge built a few Electron Beam Lithography machines based on the Stereoscan S4-10, not much more is currently known about them by the museum, more information is needed. The first currently known system at the moment, is the Stereoscan Electron Beam Microfabrication System, wich was capable of making masks down to 100nm line width, and operated from what appears to be a PDP 11/20 mini computer.
| Stereoscan EBMF (Electron Beam Microfabrication System) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||