Line 9:
Line 9:
{{Tem list entry|Microscope Name=EM-3|Microscope Picture File=AEI-EM3.png|Year=1949|Successor=|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Single Stage Electron Gun|Cathode Type=Tungsten Hairpin|Acceleration Voltage=25, 50, 75, 100 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=50|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
{{Tem list entry|Microscope Name=EM-3|Microscope Picture File=AEI-EM3.png|Year=1949|Successor=|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Single Stage Electron Gun|Cathode Type=Tungsten Hairpin|Acceleration Voltage=25, 50, 75, 100 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=50|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
−
{{Tem list entry|Microscope Name=EM-4|Microscope Picture File=|Year=1954|Successor=EM-6|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=50 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=100|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
+
{{Tem list entry|Microscope Name=EM-4|Microscope Picture File=AEI - EM4 - Agar.png|Year=1954|Successor=EM-6|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=50 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=1|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=100|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
−
{{Tem list entry|Microscope Name=EM-5|Microscope Picture File=|Year=1953|Successor=|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Cockroft Walton Accelerator|Cathode Type=Tungsten Hairpin|Acceleration Voltage=500 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
+
{{Tem list entry|Microscope Name=EM-5|Microscope Picture File=AEI - EM5 - Agar.png|Year=1953|Successor=|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Cockroft Walton Accelerator|Cathode Type=Tungsten Hairpin|Acceleration Voltage=500 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
−
{{Tem list entry|Microscope Name=EM-6|Microscope Picture File=|Year=1956|Successor=EM-6B|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=10|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=}}
+
{{Tem list entry|Microscope Name=EM-6|Microscope Picture File=AEI - EM6 - Agar.png|Year=1956|Successor=EM-6B|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=10|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=}}
{{Tem list entry|Microscope Name=EM-6M|Microscope Picture File=AEI - EM 6M - Meek.png|Year=1968|Successor=Corinth|Magnification Range=100 - 600x, 600 - 16Kx, 20Kx - 120Kx, 600 - 2500x|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=3 KVA|System Weught=1000 Kg|Accelerator Type=|Cathode Type=|Acceleration Voltage=80 Kv, (30 / 40 / 50 / 60 / 80 KV) selectable at Factory|Stability=|Cathode Heating Methode=|Alignment Methode=Mechanical|No. of Condensor Lenses=2|Condensor Stability=|Condensor Stigmator=Electrostatic Octopol|Minimum Spot Size=|Condensor Alignment=Electrostatic|Condensor Lens Type=|Holder Type=Cartridge|Travel Range=|Obj. Focal Length=4 mm|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=Electrostatic Octopole|Obj. Alignment Aid=|Point Resolution=10|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=}}
{{Tem list entry|Microscope Name=EM-6M|Microscope Picture File=AEI - EM 6M - Meek.png|Year=1968|Successor=Corinth|Magnification Range=100 - 600x, 600 - 16Kx, 20Kx - 120Kx, 600 - 2500x|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=3 KVA|System Weught=1000 Kg|Accelerator Type=|Cathode Type=|Acceleration Voltage=80 Kv, (30 / 40 / 50 / 60 / 80 KV) selectable at Factory|Stability=|Cathode Heating Methode=|Alignment Methode=Mechanical|No. of Condensor Lenses=2|Condensor Stability=|Condensor Stigmator=Electrostatic Octopol|Minimum Spot Size=|Condensor Alignment=Electrostatic|Condensor Lens Type=|Holder Type=Cartridge|Travel Range=|Obj. Focal Length=4 mm|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=Electrostatic Octopole|Obj. Alignment Aid=|Point Resolution=10|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=}}
Line 30:
Line 30:
[[Category:Electron Microscope]]
[[Category:Electron Microscope]]
+
[[Category:Pages with broken file links]]
= old list =
= old list =