Changes

Jump to navigation Jump to search
1,722 bytes added ,  22:54, 23 September 2021
Line 12: Line 12:     
{{Tem list entry|Microscope Name=EM-5|Microscope Picture File=|Year=1953|Successor=|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Cockroft Walton Accelerator|Cathode Type=Tungsten Hairpin|Acceleration Voltage=500 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
 
{{Tem list entry|Microscope Name=EM-5|Microscope Picture File=|Year=1953|Successor=|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=Cockroft Walton Accelerator|Cathode Type=Tungsten Hairpin|Acceleration Voltage=500 KV|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=Electromagnetic|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=Electromagnetic}}
 +
 +
{{Tem list entry|Microscope Name=EM-6|Microscope Picture File=|Year=1956|Successor=EM-6B|Magnification Range=|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=|System Weught=|Accelerator Type=|Cathode Type=|Acceleration Voltage=|Stability=|Cathode Heating Methode=|Alignment Methode=|No. of Condensor Lenses=|Condensor Stability=|Condensor Stigmator=|Minimum Spot Size=|Condensor Alignment=|Condensor Lens Type=|Holder Type=|Travel Range=|Obj. Focal Length=|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=|Obj. Alignment Aid=|Point Resolution=|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=}}
 +
 +
{{Tem list entry|Microscope Name=EM-6M|Microscope Picture File=AEI - EM 6M - Meek.png|Year=1968|Successor=Corinth|Magnification Range=100 - 600x, 600 - 16Kx, 20Kx - 120Kx, 600 - 2500x|Magnification Gauge Type=|Specemin Chamber Pressure=|Power Consumption=3 KVA|System Weught=1000 Kg|Accelerator Type=|Cathode Type=|Acceleration Voltage=80 (30 / 40 / 50 / 60 / 80) selectable at Factory|Stability=|Cathode Heating Methode=|Alignment Methode=Mechanical|No. of Condensor Lenses=2|Condensor Stability=|Condensor Stigmator=Electrostatic Octopol|Minimum Spot Size=|Condensor Alignment=Electrostatic|Condensor Lens Type=|Holder Type=Cartridge|Travel Range=|Obj. Focal Length=4 mm|Obj. Adjustment Range=|Obj. Spherical Error=|Obj. Stability=|Obj. Stigmator=Electrostatic Octopole|Obj. Alignment Aid=|Point Resolution=10|Obj. Lens Type=Electromagnetic|No. of Proj. Lenses=2|Proj. Stability=|Proj. Polpiece Config=|Proj. Mag=|Proj. Alignment=|Proj. Lens Type=}}
 +
 +
[[Category:Electron Microscope]]
    
= old list =
 
= old list =

Navigation menu